4–Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
59265-02 B
4-9
4.
Compare the RA_TOV and ED_TOV timeout values for all switches in the
fabric using the Show Config Switch command, or click the
Switch
tab and
Advanced icon in QuickTools. Is each timeout value the same on every
switch?
Yes—Continue.
No—Correct the timeout values on the offending switches using the
Set Config Switch CLI. Reset the port. If the condition remains,
continue.
5.
Display the active zone set on each switch using the Zoning Active
command, or click the
Active Zoneset
tab in QuickTools. Compare the zone
membership between the two active zone sets. Are they the same?
Yes—Contact your authorized maintenance provider.
No—Deactivate one of the active zone sets, or edit the conflicting
zones so that their membership is the same, and then reset the port. If
the condition remains, contact your authorized maintenance provider.
6.
Is the port connected to a switch that supports connection to a TR_Port of an
QLogic 5800V Series Fibre Channel Switch?
Yes—Configure the port as a TR_Port and map the local and remote
fabric devices.
No—Contact your authorized maintenance provider.
NOTE:
E_Port isolation can be caused by merging two fabrics whose
active zone sets have two zones with the same name, but
different membership.
Summary of Contents for SANbox 5800V Series
Page 1: ...59265 02 B Installation Guide Stackable Fibre Channel Switch 5800V Series Firmware Version 8 0...
Page 26: ...Preface Technical Support xxvi 59265 02 B...
Page 70: ...2 Planning Fabric Management 2 32 59265 02 B...
Page 90: ...3 Installation Installing Feature License Keys 3 20 59265 02 B...
Page 110: ...5 Removal Replacement Power Supply Removal and Replacement 5 4 59265 02 B...
Page 126: ...Installation Guide Stackable Fibre Channel Switch 5800V Series Glossary 8 59265 02 B...
Page 133: ......