A – Command Line Interface
Set Log Command
59097-01 A
A-75
0
Set Log Command
Specifies the events to record in the event log and display on the screen. You
determine what events to record in the switch event log using the Component,
Level, and Port keywords. You determine what events are automatically displayed
on the screen using the Display keyword. Alarms are always displayed on the
screen.
Authority
Admin session
Syntax
set log
archive
clear
component [filter_list]
display [filter]
level [filter]
port [port_list]
restore
save
start (default)
stop
Keywords
archive
Collects all log entries and stores the result in new file named
logfile
that is
maintained in switch memory where it can be downloaded using FTP. To
download
logfile
, open an FTP session, log in with account name/password of
“images” for both, and type “get logfile”.
clear
Clears all log entries.
component [filter_list]
Specifies one or more components given by [filter_list] to monitor for events. A
component is a firmware module that is responsible for a particular portion of
switch operation. Use a <space> to delimit values in the list. [filter_list] can be one
or more of the following:
All
Monitors all components. To maintain optimal switch performance, do not
use this setting with the Level keyword set to Info.
Chassis
Monitors chassis hardware components such as fans and power supplies.
Eport
Monitors all E_Ports.
Mgmtserver
Monitors management server status.
Nameserver