3 – Event Messages
Alarm Events
3-22
59060-04 A
S
(A1005.0024) (Switch must be reset after leaving the Diagnostics Admin State)
Meaning:
After changing the switch administrative state from Diagnostics to
any other state, the switch must be reset to complete the state
change.
Action:
Reset the switch.
(A1005.0034) (System resource error - contact technical support)
Meaning:
There is a system resources problem on the switch.
Action:
Contact technical support.
(A1005.0035) (System resource error - contact technical support)
Meaning:
There is an internal problem on the switch.
Action:
Contact technical support.
(A1005.0038) (Switch incompatibility error - contact technical support)
Meaning:
Switch incompatibility error.
Action:
Contact technical support.
(A1005.0039) (Fabric Login (FLOGI) from address FC_address failed)
Meaning:
The payload of the FLOGI was not valid.
Action:
Check device connection or replace the device. If the problem
persists, contact your authorized maintenance provider.
(A1005.003A) (Fabric Login (FLOGI) from address FC_address failed
authorization/authentication)
Meaning:
Security authentication failed.
Action:
Check security configuration on both the device and the switch to
ensure they are configured properly.
(A1005.003B) (Warning - Debug logging filter level is set)
Meaning:
Debug logging has been set using the Set Log Level command.
Action:
Confirm that you intended to do this. If not, use the Set Log Level
command to change the severity level to Info, Warn, or Critical.
(A1005.003C) (User Port(s) port_numbers, isolated, lost steering path, administering them
to state DOWNED.)
Meaning:
The ports required for steering the user ports have failed.
Action:
Contact your authorized maintenance provider.