background image

1

115

50

25

55

108

HORN

• Protection rating : IP55

• Ambient operating temperature : -25°C to +50°C

General Electric Horn

SRN/ SEN15/ SEN25 

Model 

number

Voltage

Current       

Sound pattern   Certificates Weight

SRN

DC12-24V

Max.

0.320A

WS - 5 Warning 

          sounds

WM - 5 Melodies

WA - 5 Alarms

WV - 5 Customiz-

          able sounds

0.72kg

AC110V

0.075A

0.98kg

AC220V

0.035A

SEN15

DC12-24V

Max.

0.370A

0.76kg

AC110V

0.080A

1.03kg

AC220V

0.040A

SEN25

DC12V

2.211A

0.95kg

DC24V

1.022A

AC110V

0.226A

1.23kg

AC220V

0.113A

SRN

-

WS

-

220

-

LC

[Model 

number]

[Sound]

[Voltage]

[Sound 

selection]

|

|

|

|

• SRN
• SEN15

• WS-Warning sounds
• WM-Melodies
• WA-Alarms
• WV-Customizable 
           sounds

• 12/24
  -DC12V-24V 
• 110- AC110V
• 220- AC220V

• 

(Blank)

- Standard type

 LC Type

 -Uses external 

   contact

• SEN25

• WS-Warning sounds
• WM-Melodies
• WA-Alarms
• WV-Customizable            
           sounds

• 12-DC12V 
• 24-DC24V
• 110- AC110V
• 220- AC220V

• 

(Blank)

- Standard type

 LC Type

 -Uses external 

   contact

 CE compliant : DC12V-24V(SRN)

  

             DC12V-24V, AC100V/220V(SEN15/SEN25)

Ordering Specifications

Product Specifications

Thank you for purchasing Qlight’s products. Please read this user manual carefully 

prior to installation and operation to ensure safe and correct use.

Precautions for Safety  

Failure to follow the instructions below may cause a loss of life or serious physical injury.

1. Please remove any objects that can interrupt ventilation around the product. 

2. Please turn off the power of the product immediately if it fails to operate properly. 

3. Carefully wire the product according to each product’s specification. 

4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product. 

5. Do not apply excessive force/impact to the product. 

6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.

Precautions for Correct Use 

Failure to follow the proper instructions may cause damage to property, the product, and or malfunction of  the 

product that would void the warranty. 

1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)

2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection 

    ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, 

    malfunction or damage to the product.)

3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to 

    follow these instructions may lead to fire, electric shock, or product damage.)

4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)

5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to 

    follow this may cause damage to property, fire, electric shock and loss of life.)

Please scan the QR code for more 

detailed product information.

www.qlight.com

Summary of Contents for SRN

Page 1: ...roduct according to each product s specification 4 Please be careful in preventing chemicals such as thinner benzene etc in contact with the surface of the product 5 Do not apply excessive force impact to the product 6 Failure to follow any of the instructions above may cause malfunction or damage to the product fire and electric shock Precautions for Correct Use Failure to follow the proper instr...

Page 2: ...xternal signal line UL1007 AWG22 0 3sq 400mm This product can be wired regardless of polarity Standard Internal switch Internal switch allows to choose sound pattern for SRN SEN15 SEN25 models SRN SEN15 SEN25 DC AC EXTERNAL CONTACT Fuse Fuse COMMON COMMON POWER POWER EXTERNAL TRANSISTOR NPN Ch 1 Ch 1 Ch 2 Ch 2 Ch 3 Ch 3 Ch 4 Ch 4 Ch 5 Ch 5 Red R Red R Amber A Amber A Green G Green G Blue B Blue B ...

Page 3: ...e upon request customized voice type 98dB 108dB The volume output of this product is adjustable Turn the volume dial clockwise to increase the volume and turn counter clockwise to decrease the volume There will be no sound when the dial is put at MIN Volume Dial VOL MAX MIN Standard unit has 5 built in sound tones Select different built in sounds using the sound setting switch ON 1 2 3 4 5 ON DP 1...

Page 4: ...Shanghai Sales Office 19 Nanda Road Baoshan Area Shanghai China Tel 86 21 6651 7100 Fax 86 21 6315 3929 Product Operation Inquiry Customer Support 82 51 620 4100 You can expect prompt service if you have exact information such as model name symptom telephone number and address ALL PRODUCT PRODUCT SPECIFICATIONS AND DATAARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY FUNCTION OR DESIGN ...

Reviews: