UM-PRORUNNER_mk9-2.0-EN
55
Electrical circuit diagrams
9
Electrical circuit diagrams
9.1
Drives
9.1.1
Drive type: SEW 3PH
Connection main power:
http://www.productliften.nl/media/text/240/247/680010306.pdf
Connection TF:
http://www.productliften.nl/media/text/240/247/681510306.pdf
Connection BR:
http://www.productliften.nl/media/text/240/247/69001006.pdf
Other connection diagrams DR:
http://www.productliften.nl/media/text/240/247/9pd0058us.pdf
9.2
Installing 87Hz
9.2.1
Wiring the drive
In a traditional wiring diagram the drive is connected in a so-called star connection. To
make sure that the drive does not lose any torque above 60Hz, it needs to be connected in
a delta configuration. The next figure shows how this can be done. To reverse the
configuration, interchange the supply leads L1 and L2.
A
Motor winding
B
Motor terminal board
C
Supply leads
D
Delta-connected, low voltage
E
Star-connected, high voltage
(E)
(D)
(C)
(C)
(B)
(A)
(A)
(B)