QIAcuity User Manual 06/2022
284
Glossary
Glossary terms are listed in alphabetical order.
Term
Description
Acquisition
The collection of fluorescent data at the end of the run
Channel
A channel consists of a light emitting diode (LED) with an excitation filter paired with an
emission filter
The LED and excitation filter excite samples at a given wavelength. Fluorescence emitted by
samples is passed through the emission filter, before being detected by the camera.
Confidence Interval
Indicates the range of values that is likely to contain the true parameter value
dPCR parameters
Parameters specifying a PCR run (e.g., number of cycles, temperature, acquisitions, etc.)
Environment
The QIAcuity Software Suite consists of several environments (e.g., “Plates”, “Templates”,
“Analysis”, “Report”). In these environments, certain tasks can be performed, such as
setting up a run or analyze data.
Error code
A 3- or 4-digit number that indicates an error of the QIAcuity
Exposure duration
The length of time the samples are exposed to light during the fluorescens acquisition
Gain
A setting to amplify the fluorescence signal
If the gain is set too high, the signal is oversaturated. If the gain is set too low, it is not
possible to differentiate signal from background noise.
GUI
Graphical user interface
Initialization
An operation performed automatically when the QIAcuity is switched on or by initiating a
self-check of the instrument, if required
Nanoplate
dPCR plate with several single partitions
Optical configuration
The optical configuration of a QIAcuity instrument is described by the available channels to
detect fluorescence signals. The optical configuration differs between different types of the
QIAcuity instruments.
Partition
Compartment in the Nanoplate where the PCR reaction takes place
Plate seal
Foil to be applied on top of the plate to prevent evaporation and contamination
Power switch
A button located at the front of the QIAcuity in the bottom-right corner
It allows the user to switch the QIAcuity on and off; inner position is ON and outer position
is OFF.
Priming
Filling of the partitions with the reaction volume
Rolling
Separation of the single partitions filled with the reaction volume
Support Package
Information wrapped up in a *.zip file to be sent via an email program to QIAGEN Technical
Services to inform QIAGEN what went wrong at the customer's site and how to help the customer
Touchscreen
The user interface that allows the user to operate the QIAcuity
VPF
Volume Precision Factor. The VPF specifies the exact cycled volume of a well within a
Nanoplate and therefore further increases precision of concentration calculation in each well.