QED MicroPurge basics MP10UH Instruction Manual Download Page 1

MP10UH

CONTROLLER

MODEL

PATENT PENDING

Instruction

Manual

P.O. Box 3726   Ann Arbor, MI  48106-3726  USA
1-800-624-2026    Fax (734) 995-1170
[email protected]    www.qedenv.com   

P/N  95177    8-22-11  

Summary of Contents for MicroPurge basics MP10UH

Page 1: ...MP10UH CONTROLLER MODEL PATENT PENDING Instruction Manual P O Box 3726 Ann Arbor MI 48106 3726 USA 1 800 624 2026 Fax 734 995 1170 info qedenv com www qedenv com P N 95177 8 22 11...

Page 2: ...MP10UH Controller Optional MP30 Drawdown Meter Well Cap Tubing Air Supply In Pump Air Supply Pump Discharge Well Wizard Bladder Pump R MP10UH Basic Setup...

Page 3: ...ection Sample Collection Flow Throttle Use Flow Throttle Use MP10UH Battery Troubleshooting MP10UH Specifications QED Service Contacts QED Warranty Appendix 1 ID Data Table Use with the MP30 Level Sen...

Page 4: ...instructions before operating and follow all safety guidelines Failure to do so may cause serious injury or death Use only the hoses and connecting fittings supplied with the MP10UH and accessories f...

Page 5: ...ttery Mode CPM ID Time R efill Discharge 00 1 1 03 1 0 0 M PC P M 4 05 0 D E D E 1 800 624 2026 micropurge com O U ED asics CONTROLLER 3 AA BATTERIES INSIDE MP10UH MODEL MicroPurge Mode Quick Guide 1...

Page 6: ...ue Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 1 03 1 0 0 M PC P M 4 05 0 D E CYCLE In MP Mode Cycle Per Minute key Changes cycle per minute Scrolls...

Page 7: ...ode the controller is in Refill time setting in seconds Time remaining in the cycle ID for time settings 4 Abbreviations Diagrams Conventions Diagrams and Conventions used in the Text cont CPM MP ID H...

Page 8: ...ptional MP30 MicroPurge Drawdown Water Level Meter plugs into the MP10UH to provide water level feedback The MP30 uses a standard conductivity probe to detect the ground water surface and a marked tap...

Page 9: ...P10UH case turns power on Note It may take up to 20 seconds for the unit to power up 6 Then set Refill and Discharge times as needed to begin and optimize pumping use initial settings of 30 seconds ea...

Page 10: ...ate the refill time should be set long enough to achieve the maximum volume of air bubbles on each pump cycle and the discharge time should be set long enough to ensure that the air has stopped bubbli...

Page 11: ...MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge QED MP10UH V1 0 BAT GOOD 4 20 D E Turning the MP10UH Display On The MP10UH is powe...

Page 12: ...sed twice from the default MP mode As shown in Figure 2 the display indicates MN mode in the lower left corner and CPM and ID are not displayed In Manual Mode the CPM and UP DOWN keys function differe...

Page 13: ...d to the pump causing the pump to discharge its volume of liquid Bladder pumps typically hold 400 500 ml of liquid so use of the Hold and Sample states allow the full volume of the pump to be discharg...

Page 14: ...es the pressure The pressure gauge shows the approximate pressure applied to the pump This allows easy adjustment of the throttle giving pressures that will produce gentle non turbulent flow normally...

Page 15: ...settings to ensure the availability of a time setting that will match your specific conditions MP mode also displays an ID with a value of 1 to 165 that matches the flow settings CPM and refill and di...

Page 16: ...arrow key could change the volume per cycle to 80 ml for example resulting in a new increased flow rate of 4 X 80 320 ml min And the MP10UH assigns a unique identification value to each setting the I...

Page 17: ...es the controller to immediately enter the Hold state Drive air is vented from the pump this is the pump refill cycle and the pump fills and waits Pressing the PAUSE key a second time causes the contr...

Page 18: ...ottle clockwise increases the pressure and counterclockwise decreases the pressure The pressure gauge shows the approximate pressure applied to the pump This allows easy adjustment of the throttle giv...

Page 19: ...e is 4 CPM 3 Turn throttle to set depth on gauge to 10 20 feet deeper than the pump location in the well 4 Press CYCLE to START pumping 5 When water discharge begins adjust throttle until a slow stead...

Page 20: ...tion so as to maintain drawdown at the set level When the water level drops below the probe the MP30 sends a signal to the MP10UH to pause pumping Both the MP10UH and the MP30 give visual signals and...

Page 21: ...MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 103 10 0 MP CPM4 05 0 D E If th...

Page 22: ...nths remove the AA batteries to prevent leakage The MP10UH power supply is automatically shut off by closing the lid Make sure the lid is closed during storage In this mode the CPM and UP DOWN keys fu...

Page 23: ...submerged when in MP mode Temperature below 10 F Warm controller Air not cycling through controller Throttle turned too low Turn throttle clockwise to produce pressure Air source not delivering air Ve...

Page 24: ...nsient surges introduced from improper battery installation or switch connect ions LCD display 32 character 2 lines 16 characters each Non glare double hardened optical acrylic 3 user replaceable AA a...

Page 25: ...yers exclusive remedy for breach of said warranty shall be as follows if and only if Q E D is notified in writing within applicable warranty period of the existence of any such defect in the said prod...

Page 26: ...pair by others is made with the written consent of Q E D If any product covered hereby is actually defective within the terms of this warranty Purchaser must contact Q E D for determination of warrant...

Page 27: ...13 5 13 12 5 12 11 5 11 10 5 9 5 9 8 5 8 7 5 7 6 5 6 5 5 5 10 30 31 32 33 34 35 36 37 38 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38...

Page 28: ...6 6 mm 1 4 1 4 6 6 mm 1 4 3 8 6 9 mm 395 ml 395 ml 395 ml 395 ml 250 75m P1101M PVC PVC 3 4 1 04 m 3 4 1 04 m 3 4 1 04 m Polypropylene Polypropylene 300 90m 300 90m 300 90m 300 90m 300 90m P1101HM St...