2 Planning
2.3 Mounting options
2 Planning
2.3 Mounting options
The module is considered to be in compliance with UL 61730 only when the module is either mounted in the manner specified by
the mounting instructions, or when the mounting means has been evaluated with this PV module to UL 2703. A module with exposed
conductive parts is considered to be in compliance with UL 61730 only when it is either electrically grounded in accordance with the
manufacturer’s instructions and the requirements of the National Electrical Code, ANSI / NFPA 70 (2014-2017), or when the bonding
means has been evaluated with this module to UL 2703.
Fig. 2:
Installation options for crystalline Qcells modules. All dimensions are given in inch (mm in brackets). Also observe the maximum
test loads and clamping range as specified on the following page.
The illustrated installation options apply for both horizontal and vertical module orientation.
Module
Clamp
Subconstruction
Mounting profile
TYPE OF
INSTALLATION
POINT MOUNTING SYSTEM
LINEAR MOUNTING SYSTEM
Installation
with clamps
CL1a
15.8-21.6
(400-550)
CL3
15.8-21.7
(400 - 550)
installation
on mounting
points
FB1
4 × mounting
slots
20
(508)
FB2
4 × mounting
slots
20
(508)
mFB2
20
(508)
Tracker
installation
on mounting
points
TB1a
39.7
(1008)
TB1b
32
(813)
39.7
(1008)
TB2a
20 or 32 or 39.7
(508 or 813 or
1008)
TB2b
32
(813)
20 or 32
(508 or 813)
TYPE OF
INSTALLATION
POINT MOUNTING SYSTEM
LINEAR MOUNTING SYSTEM
Tracker
installation
with clamps
TC1
39.7 - 41.7
(1008 -
1058)
Specifications
MODULE TYPE
MOUNTING
OPTION
POSITION OF
CLAMPS* [IN (MM)]
TEST LOAD
PUSH / PULL** [Pa]
DESIGN LOAD
PUSH / PULL** [Pa]
SAFETY
FACTOR
Q.PEAK DUO XL-G11.3 / BFG
Q.PEAK DUO XL-G11.7 / BFG
CL1a
15.8 - 21.7 (400 - 550)
3600 / 2400
2400 / 1600
1.5
CL3
15.8 - 21.7 (400 - 550)
FB1
20 (508)
5400 / 2400
3600 / 1600
FB2
20 (508)
3600 / 2400
2400 / 1600
mFB2
20 (508)
2700 / 2400
1800 / 1600
TB1b
32 (813)
2700 / 2400
1800 / 1600
TB2b
outer clamps: 32 (813)
inside clamps:
20 or 32 (508 or 813)
The below mounting options are only possible under certain conditions.
MODULE TYPE
MOUNTING
OPTION
POSITION OF
CLAMPS* [IN (MM)]
TEST LOAD
PUSH / PULL*** [Pa]
DESIGN LOAD
PUSH / PULL*** [Pa]
SAFETY
FACTOR
Q.PEAK DUO XL-G11.3 / BFG
Q.PEAK DUO XL-G11.7 / BFG
TB1a
39.7 (1008)
1600 / 1600
1060 / 1060
1.5
TB2a
outer clamps:
39.7 (1008)
inside clamps:
20 or 32 or 39.7
(508 or 813 or 1008)
2100 / 1800
1400 / 1200
TC1
39.7 - 41.7 (1008 - 1058)
1800 / 1800
1200 / 1200
*
**
***
Distance between outer edge of module and middle of the clamp (see table "2.3 Mounting options"); consider further details below.
Loads according to IEC 61215-2:2016.
Test procedure according to IEC 61215-2:2016. Loads for these mounting options do not fulfill the requirements of the standards.