Q.MOUNT INSTALLATION INSTRUCTIONS Tiled Roofs
31
POTENTIAL EQUALISATION AND CABLE MANAGEMENT
To integrate the modules into the potential equalisation, you can use the end and middle
clamp with pin. The pins are located between the clamps and module frames and thus
conductively interconnect all module rows in a module field.
Insert a wire clamp into the profile channel of the girder profiles on the first or last girder
profile of a module row. Insert the aluminium wire into the wire clamp and fix it by tightening
the screw. In this way, all module rows of a module field are conductively interconnected.
To properly secure the module cables either to the frame sides, you can use the available
cable clips to ensure that the connectors do not touch the roof cladding. Select the position
of the cable clips so that the cable plugs do not rest on the water-bearing layer.
To properly secure the module cables either to the frame sides, you can use the available
cable clips to ensure that the connectors do not touch the roof cladding. Select the position
of the cable clips so that the cable plugs do not rest on the water-bearing layer.