INSTALLATION INSTRUCTIONS 

 

Please  read  these  instructions  carefully  before  attempting  to  install  this 
product.
 It is advisable to keep these instructions in a safe place for future reference. 
Must be installed by a qualified electrician. 

 

PARAMETER: 
 

IP Rating 

IP44 

Rated Voltage 

AC 220-240V, 50Hz 

Rated Wattage 

3xMax. 100W 

Protection Class 

Class I 

Lampholder 

E27 

Electrical Installation 

Always  switch  off  the  electricity  supply  at  the  mains  during  installation  and  maintenance.  We 

recommend that the fuse is withdrawn or circuit breaker switched off at the distribution board whilst 

work is in progress (turning off the light switch is not sufficient).

 

1.  A  concrete  filled  hole  with  insulated  piping  for  the  mains  cable  need  to  be  setup.  Feed  the 

mains  cable  through  the  insulated  piping  (not  supplied)  allowing  enough  surplus  to  connect 

into the terminal block. 

We suggest that you use H05RN-F specification cable (not supplied) which is an outdoor grade, 

rubber sheathed cable. The cable must have a minimum cross sectional area of 1.0mm². 

2.  Fix the tripod (A) on top the concrete. 

3.  Insert the three anchor bolts (B) through the tripod (A) into the concrete with the threaded part 

above the ground. 

4.  The next thing can do once the concrete has dried. 

5.  Twist and remove the cover and install the lamp.   

Replacement lamp(s) should be of the same type, voltage and wattage as specified on the label. 

CAUTION:  The  lamp  will  become  hot.  Switch  off  and  allow  to  cool  before  changing  the 

lamp. 

6.  String the electric cord, from the lamp head (F) thru upper pole (E), lower pole (D) and base 

(C). 

7.  Attach the lamp head (F) onto the upper pole (E) and then secure the two together with the 

hex bolts (J3). 

8.  Connect the mains supply to the terminal block, using the following colour code for the wiring: 

Connect the Brown (Live) wire to the corresponding terminal on the terminal block marked L. 

Connect the Green/Yellow (Earth) from the mains supply to the Earth terminal marked E or 

Connect the Blue (Neutral) wire to the corresponding terminal on the terminal block marked N. 

9.  Lift  the  base  (C)  onto  the  anchor  bolts  (B)  and  secure  with  the  nut  covers  (J1)  and  locking 

washers.   

10. Attach base (C) to lower pole (D) using screws (J2) and locking washers. 

11. Thread lower pole (D) to upper pole (E) and secure with the screw. 

12. Restore mains supply and switch on. 

 