SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
753
■
H6-03 PI Function Gain
No.
(Hex.)
Name
Description
Default
(Range)
H6-03
(042E)
RUN
PI Function Gain
Sets the gain used when the function in
H6-01 [PI Pulse Train Function]
is input to terminal PI.
100.0%
(0.0 - 1000.0%)
■
H6-04 PI Function Bias
No.
(Hex.)
Name
Description
Default
(Range)
H6-04
(042F)
RUN
PI Function Bias
Sets the bias used when the function in
H6-01 [PI Pulse Train Function]
is input to terminal PI.
Sets a value when the pulse train is 0 Hz.
0.0%
(-100.0 - 100.0%)
■
H6-05 PI Filter Time
No.
(Hex.)
Name
Description
Default
(Range)
H6-05
(0430)
RUN
PI Filter Time
Sets the time constant for the primary delay filters of the pulse train input.
0.10 s
(0.00 - 2.00 s)
■
H6-06 PO Mon.Selection
No.
(Hex.)
Name
Description
Default
(Range)
H6-06
(0431)
RUN
PO Mon.Selection
Sets a function for pulse train monitor output terminal PO. Sets the
“
x-xx
”
part of the
Ux-xx
monitor.
102
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851 -
855)
Note:
To use in through mode or when terminal PO is not used, set this parameter to 000 or 031.
When you use the pulse train monitor, make sure that you connect peripheral devices as specified by these load
conditions:
Incorrect connections can make the characteristics not sufficient or cause mechanical damage.
•
Use the pulse train monitor as the sourcing output.
Output Voltage
VRL(V)
Load Impedance (k
Ω
)
5 V or more
1.5 kΩ or more
8 V or more
4.0 kΩ or more
10 V or more
10 kΩ or more
Figure 12.112 Circuit Diagram When Used as the Sourcing Output
•
Use the pulse train monitor as the sinking input
External Power Supply (V)
12 VDC
±
10%, 15 VDC
±
10%
Sinking current (mA)
16 mA or less
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Summary of Contents for Q2A
Page 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Page 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Page 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...