16
Horn Configuration
The configuration of the directivity is made by inserting two
half horns, separated by a divider, into a frame holder. The
Compression driver is fixed to this frame so there is no need to
touch it when rotating or changing the configuration. By selecting
different half horn you will be able to achieve different directives.
In the example, two 45° half horns make a 90° directivity. The
directivity of the other plane is always 50°.
1. Frame
2. Half horn
3. Divider
Directivity
Model
Default Configuration
Optional Directivity
PL-DC24
110 x 50°
120°
110°
90°
120°
None
PL-DC26
120 x 50° (Vertical Deployment)
120°
110°
90°
120°
90 x 50°
105 x 50° Asymmetrical (Half Horn 45 + Half Horn 60)
= 90°
3
2
1