Zone 4 Sensor Type: sets the Zone 4 (Sensor 2) name to be displayed in the Text Field for Warn-away
1.
and Full Trigger activations
Siren Duration: sets the Full Trigger output duration in 1 second intervals up to 180 seconds.
2.
Aux/Trunk Icon Type: sets the Accessory animation to be displayed on the screen when the Aux/Trunk
3.
output is activated/de-activated
Aux 1 Timed Output: sets the output duration in 1 second intervals up to 90 seconds for Aux 1
4.
Aux 1 Icon Type: sets the Accessory animation to be displayed on the screen when the Aux 1 output is
5.
activated/de-activated
Aux 2 Timed Output: sets the Aux 2 “Timed” output in 1 second intervals up to 90 seconds
6.
Aux 2 Icon Type: sets the Accessory animation to be displayed on the screen when the Aux 2 output is
7.
activated/de-activated
Aux 3 Timed Output: sets the Aux 3 “Timed” output in 1 second intervals up to 90 seconds
8.
Aux 3 Icon Type: sets the Accessory animation to be displayed on the screen when the Aux 3 output is
9.
activated/de-activated
Aux 4 Timed Output: sets the Aux 4 “Timed” output in 1 second intervals up to 90 seconds
10.
Diesel Start Delay Timer: sets the delay before engine crank in 1 second intervals up to 90 seconds for
11.
diesel engine vehicles
Timer Mode Runtime: sets the duration of runtime when the engine is started by the Timer Mode and Smart
12.
Start features
Timer mode Starts: sets the number of times the engine will be started by the Timer Mode and Smart Start
13.
features
Timer mode Intervals: sets the number of hours between engine starts by the Timer Mode and Smart Start
14.
features
Smart Start Low Temperature: sets the low temperature threshold required for Smart Start to start the
15.
engine
Smart Start High Temperature: sets the high temperature threshold required for Smart Start to start the
16.
engine
Smart Start Low battery (Volts): sets the low battery level threshold required for Smart Start to start the
17.
engine
Sensor 1 level: directly sets the sensor level of the on-board shock sensor
18.
Starter Release Fine Tune: adds or subtracts crank time in Tachometer mode in order to overcome engine
19.
types that short crank or over-crank on the first start attempt
Feature Programming: locks and unlocks the user’s ability to enter the feature menus and manually
20.
change the main unit programming using the Control Center
Transmitter Programming: locks and unlocks the user’s ability to enter the remote control/Reset menu and
21.
manually change any functions using the Control Center
Remote Start Runtime: sets the duration of runtime when the engine is started by remote command
22.
VirtualTach Fine tune: adds or subtracts crank time in VirtualTach mode in order to overcome engine types
23.