background image

BREAKGLASS 

2000/BG16DF

 

TESTER

GENERAL  DESCRIPTION

This unique tester has been designed 
specifically for testing the BreakGlass 

detector.

By  simulating the sound of breaking

 glass the Breakglass Tester offers 

a way of correcting the sensitivity

 of the Breakglass  detector ensuring

 good detection and performance 

at all times.   

  

    

     

 

 

RINS 301-4

This product is approved for use in the 

Residential, Commercial and Light Industrial Environment.

OPERATIONAL SWITCHES

OFF - 

Tester switched off.

NORMAL 

- Press the trigger when in normal mode to   

                   

Generate a loud breaking glass sound.

FLEX -

 In Flex mode, pressing the trigger arms the unit.   

           

 To create a flex condition thump the protected 

            glass in a controlled manner. 
            This will cause the Breakglass Tester to 
            generate a breaking glass sound.      
 

TRIGGER -

 Creates glass break sound.  

TEST PROCEDURE

Step 1 - 

Take the cover off the detector and place in test mode.

Step 2 - 

Set sensitivity to minimum.

Step 3 - 

Place the tester next to the window, which is to be protected.

Step 4 - 

Switch the tester into flex mode.

Step 5 - 

Arm the tester by pressing the trigger button.

Step 6

 - Thump the glass lightly to simulate object hitting the window.

Step 7

 - When the Tester simulates breaking glass check all the LED

              indicators on the Breakglass detector.
              The indicators will illuminate in the following order indicating 
              a good activation. (Green, Orange and Red)

Step 8

 - Adjust the sensitivity as required to gain the best LED indication.

              (After sensitivity adjustment re-test)
              

Step 9

 - Replace cover on detector.

Step 10

 -Note See Breakglass instructions  for further 

               information on detector.   

 

  

LOUD NOISE

SAFETY           

The Breakglass tester produces loud sounds, always direct the tester away from the ear
when in use.

SPECIFICATIONS

Operating Voltage - 9V Battery 

Battery Life - 2000+ Operations 

Simulated Glass -  Plate glass

Operating Temperature  -10  C to 40  C

Storage Temperature  -20  C to 60  C 

STEP 1

Sensitivity adjustment

Min

Max

STEP 2

STEP 7

GREEN         =  Flex activation.
ORANGE =  Shatter activation.
RED    =  Alarm  Activation

LED Indicators

BREAKGLASS

2000 

Tester

TRIGGER

FLEX 
    NORMAL
OFF

TM

LOUD NOISE

TRIGGER

FLEX 
    NORMAL
OFF

100mm

1

9

0

m

m

35 mm

WARRANTY

This product is sold subject to our standard warranty 

conditions and is warranted against defects in workmanship for 

a period of 2 years. In the interest of continuing improvement 

of quality, customer care and design Pyronix LTD reserve 

the right to amend specifications without giving 

prior notice.   

Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND

Tel:  0845 6434 999
or   +44(0)1709 535225

Hours: Monday to Friday, 8:00am - 6:30pm

email: [email protected]