Page 2: ...ion 11 5 6 Default settings and device errors 12 5 6 1 Restore default settings 13 6 Button control 13 7 DMX signal connecting 14 8 RDM available parameters 14 9 Programming 16 10 Connection scheme 17 11 Dimensions 19 12 Technical data 20 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek Żupnik sp k Podłęże 654 32 003 Podłęże BDO register number 0...
Page 3: ... relays that control the on off outputs Device has a built in hysteresis system that activates the output after exceeding the value 136 of the DMX signal The relay is turned off below the value 119 The method of operation is shown in the figure below The device is equipped with a DMX signal input and output It is produced in a housing adapted for mounting on a 35mm DIN rail The PX815 is designed t...
Page 4: ... the event of damaging any conductor it should be replaced with a conductor of the same technical data 4 Connection of DMX signal can only be made with shielded conductor 5 All repairs and connections of outputs or DMX signal can only be made with cut off power supply 6 The PX815 should be strictly protected against contact with water and other liquids 7 To connect the control outputs use only cab...
Page 5: ...than 2 C or higher than 40 C 12 Clean with damp duster only the PX815 must be completely disconnected from the power supply and control connectors at this time 13 The relays must be protected by a depending on version max 13A or max 16A type C overcurrent fuses 5 ...
Page 6: ...ED signaling in the PX815 2 may differ from the version presented in the description of the connectors and control elements above PX815 3 6 control connectors display programming buttons DMX LED control LEDs for control connectors power supply 12 24V DC DMX input DMX output ...
Page 7: ... selection turning on the output turning off the output maintaining the last value before the disappearance of the DMX signal channel selection device temperature the operating temperature has been exceeded thermistor shorted missing thermistor or thermistor open restore default settings on the device firmware version serial number 7 ...
Page 8: ...currently programmed parameter without saving the changes or moving to the higher level in the menu prev scrolls backwards in the menu or reduces the values to be set next scrolls forwards in the menu or increases the values to be set enter causes entering the device programming and confirms the set values 5 2 Information parameters PX815 allows to display information on the device s software vers...
Page 9: ...nel 512 With the buttons next or prev you can set the DMX address by selecting a value from 1 to 512 and then confirm with the enter button The set address will be assigned to the first channel subsequent DMX addresses will be assigned to the next channels For example for the PX815 3 version setting the DMX 511 address will result in assigning the DMX 511 address to channel 1 and the address 512 t...
Page 10: ...n of the device to the disappearance of DMX signal for each channel individually The possible options are OFF switching off the channel On switching on the channel HLD maintenance of the last DMX values 10 ENTER ENTER NEXT NEXT ENTER NEXT NEXT NEXT PX815 2 version ...
Page 11: ...he temperature of 80 C Reactivation will take place after the device cools down to the temperature of 70 C If the temperature is exceeded the screen alternately displays the DMX address and the message and the LEDs of the control connectors blink The operation of this function is shown in the diagram below 11 ENTER ENTER 2 x NEXT state temperature 70 C ON OFF 80 C ON OFF ...
Page 12: ...correctly this may indicate that a saving in memory error has occurred In such a case try to restore the device to its default settings before sending the PX815 to the service center If after restoring to its default settings the device still does not operate correctly please send it to our service center Temperature measurement error messages thermistor shorted missing thermistor or thermistor op...
Page 13: ... reset After restoring to default settings the settings will be changed to DMX address 1 no signal mode off all channels 6 Button control The combination of the esc pressed next prev enter 1 x click buttons allows to activate buttons or deactivate control channels esc prev enable or disable channel 1 esc next enable or disable channel 2 esc enter enable or disable channel 3 NOTE In PX815 2 the esc...
Page 14: ...N DMX THRU GND GND CORRECT DMX 512 input DMX 512 output DMX IN DMX THRU GND GND WRONG DMX 512 line DMX IN DMX THRU GND GND TERMINATOR CONNECTION DMX 512 input 120 Ohm 8 RDM available parameters The PX815 supports the DMX RDM protocol DMX protocol allows only of a one way data transmission while its extension the RDM protocol can transmit information in two directions This makes possible to simulta...
Page 15: ...states are possible identification is off 0x00 value and identification is on 0x01 value DEV_MODEL_DESC 0x0080 device description e g name MANUFACTURER_LABEL 0x0081 manufacturer description e g name DEVICE_LABEL 0x0082 additional device description It is possible to enter an additional device description using up to 32 ASCII characters FACTORY_DEFAULTS 0x0090 device default settings PERSONALITY 0x...
Page 16: ...MX signal only in 2 and 3 channel version NOS3_OFF ON HLD 0x801F setting the reaction to the disappearance of DMX signal only in 3 channel version SERIAL_NUMBER 0x8030 device serial number editable parameter 9 Programming 16 ENTER ENTER NEXT ENTER NEXT NEXT ENTER NEXT NEXT ENTER NEXT ENTER ESC NEXT ENTER ENTER NEXT ENTER ENTER Example serial number 21 187 004 NEXT Pressed ENTER ...
Page 17: ...puts with different phases NOTE The layout of the connectors and LED signaling in PX815 3 may differ from the version shown in the example connection diagram above PX815 2 17 L L N L 230 V AC phase 1 overcurrent fuse 16A overcurrent fuse 16A receivers e g lamps L N 230 V AC phase 2 ...
Page 18: ...nnectors and LED signaling in PX815 2 may differ from the version shown in the example connection diagram above PX815 3 NOTE A time interval of 100ms has been implemented between the switching on of successive outputs 18 230 V AC N L overcurrent fuse 13A receivers e g lamps ...
Page 19: ...11 Dimensions NOTE The layout of the connectors and LED signaling in PX815 2 may differ from the version shown in the technical drawing above PX815 3 19 45 58 90 52 ...
Page 20: ...ithout load max 2W number of output channels PX815 2 2 PX815 3 3 output load PX815 2 16A channel PX815 3 13A channel relay voltage max 240V AC loss of power PX815 2 0 5W channel PX815 3 0 8W channel maximum inrush current 500A 2ms output connections screw terminal weight 0 2kg dimensions width 52mm height 90mm depth 58mm 20 ...
Page 21: ...0 6 3 2008 EN IEC 63000 2018 EN 61000 4 2 2009 EN IEC 61000 6 1 2019 EN 61000 6 3 2007 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Text with EEA relevance 2014 30 UE DIRECTIVE OF THE EUROPEAN PARL...