background image

PX746

Driver LED

3 x 700mA/48V

User manual

Summary of Contents for PX746

Page 1: ...PX746 Driver LED 3 x 700mA 48V User manual...

Page 2: ...al response 14 5 6 Description of programs 15 5 7 Master Slave function 17 5 8 White balance 18 5 9 Smooth 19 5 10 Light control frequency 20 5 11 Screen saving screen blanking 21 5 12 Temperatures li...

Page 3: ...rves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e BDO register number 000005972 tel 48 12 385 83 06 mail info pxm pl www pxm pl Rev...

Page 4: ...6 bit resolution controlling the parameters of channels is completely smooth Moreover the driver offers an effect control mode which allows for controlling the programs that are built into the device...

Page 5: ...technical data 2 All the conductors should be protected against mechanical and thermal damage 3 In the event of damaging any conductor it should be replaced with a conductor of the same technical data...

Page 6: ...10 Clean with damp duster only 3 Connectors and control elements 6 PX746 3x700 mA 48V display programming keys power supply 12 48V DC NTC 4K7 temperature sensor DMX output DMX input control outputs...

Page 7: ...ion RGB Lightness Colour etc no DMX signal response method selection Master Slave mode settings Lightness Colour control mode RGB control mode RGB Dimmer control mode HSL control mode Hue Saturation L...

Page 8: ...sage restore default device settings menu function to limit power value of the limit activation temperature value of the maximum limit temperature current temperature the highest temperature recorded...

Page 9: ...previous scrolls to the previous feature on the same MENU level or decreases the parameter s value next scrolls to the next feature on the same MENU level or increases the parameter s value enter ent...

Page 10: ...hat allows for changing individual settings It enables assigning any DMX address to every output channel The simplest example of implementation of this function is to control the lightness of one colo...

Page 11: ...xt page 11 ENTER NEXT ENTER ENTER NEXT NEXT NEXT NEXT NEXT The PX746 driver can operate in different control modes Depending on the selected mode the devices takes up a different numbers of channels p...

Page 12: ...nel 4 operating mode selection Channel 5 speed settings higher value quicker changes Channel 6 fade settings higher value smoother transition Channel 7 lightness settings higher value stronger glow si...

Page 13: ...47 Program 6 x x x 48 55 Program 7 x x x 56 63 Program 8 x x x 64 71 Program 9 x x x 72 79 Program 10 x x x 80 87 Program 11 x x x 88 95 Program 12 x x x 96 103 Program 13 x x x 104 111 Program 14 x x...

Page 14: ...he DMX signal will automatically break the realized function and the module will once again follow the commands transmitted via the DMX line P01 P18 choosing a ready program provided in the device sof...

Page 15: ...tivation of all outputs at 100 with the possibility of setting the switch on time SPd all outputs after decay DMX signal oFF disabling all outputs after DMX signal loss 5 6 Description of programs The...

Page 16: ...0 255 0 0 Step 2 R 0 0 255 0 255 255 255 0 0 G 255 255 0 0 255 0 0 255 0 B 0 0 0 255 0 255 255 0 255 Step 3 R 0 255 0 0 0 0 255 G 0 0 0 0 255 0 255 B 255 0 0 0 0 255 0 Step 4 R 0 0 0 0 G 255 255 255 2...

Page 17: ...rd Moreover it is equipped with a programmable function of response to no DMX signal noS With 18 built in default programs it is possible to obtain interesting effects without an external controller H...

Page 18: ...nt technical parameters For this reason the PX746 module is equipped with a white balance function This option allows for choosing a correct colour temperature for full activation of all 3 outputs whi...

Page 19: ...e smoothed linearly between the DMX signal packets for the selected option or the time interval set in the menu in range 10 999ms The smooth function may slightly slow down the lamp s response rate to...

Page 20: ...ing effect which is caused by improper signal synchronization that controls the LEDs The user can choose from the available frequency range from 366Hz up to 25 0kHz which can be smoothly changed using...

Page 21: ...ithout interfering with other parameters Press any key to restore the backlight 5 12 Temperatures limits and sensor failure PX746 has been equipped with a function that limits the output power dependi...

Page 22: ...ue can be set between 30 C and 60 C Hi maximum limit temperature value set in the range from 70 up to 90 C t C current temperature tSH the highest temperature recorded by the sensor tSL the lowest tem...

Page 23: ...ensor or disable the temperature limit 5 13 Display function As the driver should be installed As far as possible in a small distance from the controlled LEDs the lack of space may force the necessity...

Page 24: ...t possible to enter a particular menu level or it is necessary to restore the device to its default settings follow the instructions below In the first case when a particular menu level cannot be acce...

Page 25: ...d If this message is accepted by pressing enter the default settings will be restored The user can also exit this menu level without restoring the default settings In order to do this press the escape...

Page 26: ...must be sent to the service point 6 DMX signal connecting PX746 have to be connected to DMX line in serial mode with no branches on DMX control cable That means that DMX line from the signal source mu...

Page 27: ...ol List of RDM parameters supported by the PX746 Parameter name PiD Description SUPPORTED_PARAMETERS 0x0050 all supported parameters PARAMETER_DESCRIPTION 0x0051 description of additional parameters D...

Page 28: ...00 operating time counted in hours TEMPERATURE_LIMIT_ ON OFF 0x800E temperature limitation activation for the temperature sensor connected to the driver TEMPERATURE_ THRESHOLD_LOW 0x800F lower tempera...

Page 29: ...value for scene saved in PX746 SCENE_GREEN 0x801E settings of green channel value for scene saved in PX746 SCENE_BLUE 0x801F settings of blue channel value for scene saved in PX746 SCREENSAVER_ON OFF...

Page 30: ...8 Programming 30 ENTER ENTER NEXT ENTER NEXT NEXT ENTER NEXT NEXT NEXT ENTER NEXT NEXT NEXT NEXT ENTER ENTER NEXT NEXT NEXT ENTER NEXT ENTER ENTER NEXT NEXT NEXT Next page NEXT NEXT...

Page 31: ...31 ENTER ENTER NEXT NEXT NEXT ENTER NEXT NEXT ENTER NEXT NEXT ENTER NEXT ENTER NEXT NEXT NEXT NEXT NEXT ENTER NEXT NEXT NEXT NEXT NEXT Previous page...

Page 32: ...rome lamp connection one colour 700mA power supply LED driver Power supply Number of diodes of one color LED driver Power supply Number of diodes of one color PX746 12V 1 3 PX746 12V 3 24V 4 6 24V 6 4...

Page 33: ...should be connected only in series controlled LEDs can be connected using two conductors only i e two per channel the number of serially connected LEDs depends on the driver and supply voltage 33 LED...

Page 34: ...stor The connection of the NTC 4K7 thermistor is applicable only when one lamp is connected to the driver This is due to the fact that the device can read the temperature from only one lamp 34 PX746 d...

Page 35: ...Monochrome lamp in DW mode connection diagram 35 RED cold white warm white mono GREEN BLUE BLUE GREEN RED PX746 driver...

Page 36: ...10 Dimensions 36 44 8 192 20 6 PX746 3x700 mA 48V...

Page 37: ...ax current consumption 2 1A no load power consumption 0 5W output load capacity 700mA channel 2 5 output sockets PCB terminal block wire 0 5 1 5mm2 number of programmable scene 1 built in programs 18...

Page 38: ...0 2018 EN 61000 4 2 2009 EN IEC 61000 6 1 2019 EN 61000 6 3 2007 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of...