  Recoveries based on 83% thermal efficiency.  ASHRAE 90.1 compliant for efficiency and standby loss. 
   "J" dimension is for the burner housing only.  Gas train may exceed this dimension. 

 

Standard gas train. 

*

  The information presented is for Natural gas 0.6 S.G.— For operation with propane (LP gas), consult factory. 

  

Dimensions are in inches unless otherwise specified. 

 

Higher inputs available. Consult the factory. 

 

For standard and optional equipment, see form PV 6046. 

Model 

Number 

Recovery gph 

 

Input 

Btu/h 

Min. Inlet Flow 

Gas Pressure 

"W.C.   

#2 Oil 

gph 

Dimensions (inches) 

Blower  

Motor 

Shipping 

Weight 

lbs  

40°- 120°F  40°- 140°F 

 

HP 

Volt/Ph/

Amps 

750 N 600A-TPGO 

750 

600 

600,000 

4.5 

4.3 

46 

31 

1/2 

115/1

/10 

2720 

1000 N 600A-TPGO 

1000 

800 

800,000 

6.0 

5.7 

46 

31 

1/2 

115/1

/10 

2760 

1250 N 600A-TPGO 

1250 

1000 

1,000,000 

7.5 

7.2 

54 

31 

3/4 

115/1

/14 

2850 

1500 N 600A-TPGO 

1500 

1200 

1,200,000 

7.5 

8.6 

54 

1-1/4 

31 

115/1

/16 

2930 

2000 N 600A-TPGO 

2000 

1600 

1,600,000 

6.5 

11.4 

63 

10 

36 

115/1/

24 

3140 

2500 N 600A-TPGO 

2500 

2000 

2,0

0

0,000 

8.0 

14.3 

65 

10 

36 

115/1

/24 

3260 

TURBOPOWER

®

  GAS/OIL  

 

PACKAGED WATER HEATER 

NICKELSHIELD

®

 

NICKEL-PLATED STORAGE TANK

 

TANK SERIES 600 GALLONS 

PV 5460  03/04 

PVI INDUSTRIES, LLC 

FORT WORTH, TEXAS 76111 

(800) 784-8326 

 

(817) 335-9531 

 

www.pvi.com 

Product is patented in the U.S., Canada, and Mexico. 

STANDARD ELECTRICAL REQUIREMENTS 

  CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS. 
  MOTOR VOLTAGE:  
  208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL 
  REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN 
  OPTIONAL CONTROL CIRCUIT TRANSFORMER. 

*

 REAR ACCESS MODULE 

MODEL PREFIX 

STD or OPTIONAL 

750-1500 

23" 

8" 

OPTIONAL 

2000-2500 

23" 

16" 

STANDARD 

 

*

 GAS PRESSURE REQUIREMENTS 

SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER. 

MAXIMUM STATIC INLET PRESSURE: 14" W.C.

 

FOR PRESSURES OTHER THAN LISTED, CONSULT FACTORY. 

Pressure shown is for standard UL gas train. Additional controls 

may increase pressure requirements. 

VENTING REQUIREMENTS 

-.02" TO -.06" W.C. (NEGATIVE PRESSURE) 

 

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED 

UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.  

FOR PROPER SIZING, CONSULT  

THE NATIONAL FUEL GAS CODE UNDER “FAN-ASSISTED.” 

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN 

AND SPECIFICATION WITHOUT NOTICE. 