PVI Industries 1000N400A-TPO Specification Sheet Download Page 1

  Recoveries based on 83% thermal efficiency.  ASHRAE 90.1 compliant for efficiency and standby loss. 
   "J" dimension is for the burner housing only.  
  4" x 42" Channel skids for inputs 

 1000 MBtu/h. 

 

4" x 53" Channel skids for inputs > 1000 MBtu/h. 

 

Dimensions are in inches unless otherwise specified. 

 

For standard and optional equipment, see form PV 6004.  

 

Model 

Number 

Recovery gph 

 

Input 

Btu/h 

Dimensions (inches) 

Blower  

Motor 

Shipping 

Weight 

lbs  

40°- 120°F  40°- 140°F 

 

HP 

Volt/Ph/

Amps 

250 N 400A-TPO 

250 

200 

199,000 

29 

17 

1/3 

115/1

/8 

1700 

500 N 400A-TPO 

500 

400 

399,000 

29 

17 

1/2 

115/1

/10 

1720 

750 N 400A-TPO 

750 

600 

600,000 

32 

17 

1/2 

115/1

/10 

1800 

1000 N 400A-TPO 

1000 

800 

800,000 

32 

17 

1/2 

115/1

/10 

1840 

1250 N 400A-TPO 

1250 

1000 

1,000,000 

49 

17 

1/2 

115/1

/10 

2080 

1500 N 400A-TPO 

1500 

1200 

1,200,000 

49 

17 

1/2 

115/1

/10 

2090 

Gph 

#2 Oil 

1.4 
2.8 
4.3 
5.7 
7.2 
8.6 

2000 N 400A-TPO 

2000 

1600 

1,600,000 

11.4 

61 

10 

25 

1-1/2 

115/1

/20 

2530 

2500 N 400A-TPO 

2500 

2000 

2,000,000 

14.3 

61 

10 

25 

1-1/2 

115/1

/20 

2550 

3000 N 400A-TPO 

3000 

2400 

2,400,000 

17.1 

60 

12 

25 

1-1/2 

115/1

/20 

2560 

3500 N 400A-TPO 

3500 

2800 

2,800,000 

20.0 

60 

12 

25 

230/3

/16 

2590 

4000 N 400A-TPO 

4000 

3200 

3,200,000 

22.8 

60 

12 

25 

230/3

/16 

2640 

39 
39 
39 
39 
39 
39 
39 
39 
50 
50 
50 

TURBOPOWER

®

  OIL 

 

PACKAGED WATER HEATER 

NICKELSHIELD

®

 

NICKEL-PLATED STORAGE TANK

 

TANK SERIES 400 GALLONS  

PV 5420  04/05 

PVI INDUSTRIES, LLC 

FORT WORTH, TEXAS 76111 

(800) 784-8326 

 

(817) 335-9531 

 

www.pvi.com 

Product is patented in the U.S., Canada, and Mexico. 

VENTING REQUIREMENTS 

-.02" TO -.06" W.C. (NEGATIVE PRESSURE) 

 

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED 

UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.  

FOR PROPER SIZING, CONSULT VENTING SUPPLIER. 

STANDARD ELECTRICAL REQUIREMENTS 

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS. 
  MOTOR VOLTAGE:  
  208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL 
  REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN 
  OPTIONAL CONTROL CIRCUIT TRANSFORMER. 

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN 

AND SPECIFICATION WITHOUT NOTICE. 

* REAR ACCESS MODULE 

MODEL PREFIX 

STD or OPTIONAL 

250-1500 

23" 

8" 

OPTIONAL 

2000-2500 

23" 

18" 

STANDARD 

3000-4000 

30" 

25" 

STANDARD 

Reviews: