![PVA Sigma Owner'S Manual Download Page 49](http://html.mh-extra.com/html/pva/sigma/sigma_owners-manual_1628591049.webp)
Sigma Operation Manual
Revision B
/
July 2020
Page 49 of 68
Connect Web Interface to Existing Network
There is an option to connect an existing 2.4 GHz WiFi network to the web interface.
Note: This option is not compatible with 5 GHz networks.
1.
Use the steps outlined in Sigma Wireless Connection Setup to connect to Sigma’s
WiFi network.
2.
Once connected, access the web interface.
3.
Navigate to the G-Code Console.
Figure 53: G-code Console
M587 Command
The M587 command will be used to send your desired network information to the web
interface’s G-code console. The M587 command must include three components.
1.
S
: Network SSID
•
Must be enclosed in quotation marks
•
Case-sensitive
2.
P
: Network Password
•
Must be enclosed in quotation marks
•
Case-sensitive
3.
I
: IP address to use when connected to this network (optional).
•
If zero is entered or not specified, an IP address will be acquired via DHCP.
The M587 command must be written in the following format:
M587
S
”WIFI_NETWORK_NAME”
P
”PASSWORD”
I
x.xxx.xx.xxx