RD100 & RD200 PVA
Revision A (2016)
20 of 35
Setup Valve
NOTE: If you have only one Rotary table, you will have only one screen.
16.
Use the up and down arrows to scroll to the Setup Valve screen(s).
17.
Use the buttons on the left and right of the screen to toggle the
Valve
or the
Z-
Slide
between
Enable
and
Disable.
Figure 18: Setup Valve L and R
18.
Use the left and right arrows to select the
Start Time
or
Stop Time
speed you
want to change. Select
Enter.
Start time is the time the valve starts to dispense
before the rotary table moves. Stop time is the time the valve continues to
dispense after the rotary table has stopped moving.
19.
Use the key pad to enter the new value.
20.
Select
Enter
to save the new value.
Shutdown
Make sure the system is correctly shutdown when it is not in use.
1.
If the system is in the middle of a cycle, let it finish.
2.
Push the “
ESC
” button on the HMI to return to the home screen.
3.
Engage the
Emergency Stop
button.
4.
Reduce the system pressure to 0psi.
5.
Turn the main power to “
Off
”.
6.
If maintenance will be done, lock-out and tag-out the system.