5.
Pull the static mixer straight down, off the PC200 valve manifold so there is
a small space between the static mixer and the manifold.
6.
Use the purge function on the machine controller to purge material until it
overflows from the top of the static mixer. Let all air release from the top of
the static mixer.
7.
Push the static mixer firmly back onto the PC200 manifold.
8.
Clean the material completely off of the static mixer and PC200 valve.
Figure 5: Purge the Static Mixer
9.
Put the static mixer retaining nut on and use a wrench to tighten.
10.
Install the desired needle on the end of the static mixer.
11.
Use the purge function on the machine controller to purge material through
the static mixer. Purge the volume of the entire static mixer to fill it with
fresh material.
12.
Push and release the purge button. Examine the static mixer for drips after
the material has dispensed.
13.
If it continues to drip, do steps 3-13 again. Drips from the tip of the static
mixer are caused by air that is trapped inside.
14.
If the static mixer does not drip, the valve is ready to dispense.