![PVA Endurance Owner'S Manual Download Page 14](http://html.mh-extra.com/html/pva/endurance/endurance_owners-manual_1628588014.webp)
Endurance Operation Manual
REV A
/
October 2020
Page 14 of 132
Installation and Setup
WARNING: The following procedures should be performed by qualified persons in
accordance with this manual and applicable safety regulations. A “qualified person”
is defined as “a person or persons who, by possession of a recognized degree or
certificate or professional training, or who, by extensive knowledge, training, and
experience, has successfully demonstrated the ability to solve problems relating to
the subject matter and work.” (ref. ANSI/ASME B30.2
-1983.)
Unpacking and Inspection
1.
Remove all packing materials and strapping. Thoroughly inspect the exterior of the
machine for damage, loose fasteners, etc.
2.
Inspect all tubing connections, gauges, and regulators.
Installation
Plug the machine into an appropriate power source as determined by the configuration
section of the operating guide or the legend plate on the rear of the machine. The
electrical service should be properly grounded, and the power sources should be clean. If
there is high power equipment operating off the same source, a line conditioner may be
necessary. Errors in machine operation could indicate poor quality power.
WARNING: Failure to comply with electrical specifications can result in damage to
the machine as well as injury to installation personnel. Electrical hookup must be
made by a qualified electrician and must comply with any applicable local standards.
1.
A ¼” NPT female fitting is provided at the rear of the machine.
Connect to a source
of clean, dry air.
A hose of ¼” inside diameter is sufficient.
2.
Ground any pressure vessel to earth or the machine.
NOTE: Precision Valve & Automation STRONGLY recommends the machine not be
powered on or material added to the pressure vessels until they are properly
grounded.
3.
Close any access doors and push in the EMERGENCY STOP button. Turn on the red
air lockout valve.
4.
Turn on power at red switch on the side of the electrical enclosure.