DeltaTherm IR Cure Module
Revision B
/
February 2020
Page 30 of 41
Fault Recovery Procedure
Several errors can cause a fault condition. They are:
•
The EMERGENCY STOP is engaged or there is an open door
•
There is an exhaust or intake fan failure
•
The parameters are out of range
•
The module is over-temperature
•
There is a solid-state relay failure
The following sections show an example of a machine error. For a complete list of error
messages, refer to
Recovery from Emergency Stop or Open Door Error
If the Emergency Stop button is engaged or the machine has a system error, perform the
following procedure to return the machine to the cycle stop state.
WARNING: If the Emergency Stop was engaged because of system failure, do not
disengage the Emergency Stop. Shutdown the system and have qualified personnel
repair the machine.
1.
Disengage the Emergency Stop button or close all doors.
2.
Select “Clear Fault”.
Recovery from an Exhaust or Intake Fan Failure
1.
Select “
Clear Fault
” to stop the alarm or “
Reset
” to clear the fault.
2.
Operate the fan in Manual mode to make sure the components operate correctly.
Recovery from a Parameter Out of Range Error
1.
Select “
Silence Horn
” to stop the alarm or “
Clear Fault
” to clear the fault.
2.
Operate the module in manual mode or restart the Auto Cycle. Look for the
parameter that causes the error.
3.