DeltaTherm IR Cure Module
Revision B
/
February 2020
Page 20 of 41
Manual Mode
IR Panels
The panel temperature is shown for each zone. A zone is an area in the oven that is
controlled and monitored independent of other areas. Usually an oven has four zones.
Figure 12: Manual IR Panels
1.
Select the
Heater Panel
switch to turn the desired panel on or off. The indicator to
the left of the switch will show the heat output. The heater panel will heat up to the
current setpoint.
2.
The
Setpoint
boxes are the target set points for each zone and heater panel. To
change the target
Setpoint
, press the designated box. A new screen will be shown.
•
The left side box in the Zone Control area is the target temperature (display
temperature is filtered) for each zone and the deviation point for that zone.
•
Touch the screen and a keypad will be shown.
•
Enter the necessary value.
•
Push
ENT
, and the zone screen will be shown again.
3.
The
Actual
boxes show the actual temperatures (display temperature is filtered) for
each zone.
4.
Select
Apply to All
to copy the setpoints of the Zone 1 upper and lower heater panel
to every zone and panel.
5.
Select the
View Trend
icon to view each panel’s temperature history on a graph.