![PV Powered PVP2000 Installation & Operation Manual Download Page 55](http://html.mh-extra.com/html/pv-powered/pvp2000/pvp2000_installation-and-operation-manual_1628545055.webp)
43
Appendix A - Specifications
The specifications detailed below are expected operational parameters, and
should be used in designing your PV system in accordance with the NEC.
A.1 Inverter Specifications
Specifications
PVP1100
PVP2000
PVP2500
PVP2800
Maximum DC Input Voltage (VOC)
500VDC
DC Voltage Operating Range (V)
115VDC-
450VDC
115VDC-
450VDC
140VDC-
450VDC
180VDC-
450VDC
DC MPPT Range (V)
115VDC-
380VDC
115VDC-
380VDC
140VDC-
380VDC
180VDC-
380VDC
DC Imp Maximum Current (A)
10A
18A
20A
18A
DC Isc Maximum Current (A)
26A
AC Operating Range (V)
105.6V-
132.5V
211V-
264V
211V-
264V
183V-
229V
AC Frequency Range (Hz)
59.3Hz-60.5Hz
AC Nominal Voltage (V)
120V
240V
240V
208V
Normal Output Frequency
60Hz
Synchronization in Rush Current
< 2.0A
8.4A
< 2.0A
Power Factor
0.99 - 1.0 at > 50% Power
AC Maximum Continuous Current (A)
10A
9A
11A
13A
Continuous Output Power (Watts)
1100
2000
2500
2800
Maximum Continuous Output Power
(Watts)
1100
2000
2500
2800
Enclosure
Steel- NEMA 3R to UL 50 Standards
Dimensions (H x W x D)
With AC/DC Disconnect (H x W x D)
22 1/2” x 15 5/8” x 8 1/4”
(57.15cm x 39.69cm x 21cm)
30 3/8” x 15 5/8” x 8 1/4”
(77cm x 39.69cm x 21cm)
Weight (lbs)
84.5 (38 kg) 92.5 (42 kg) 106.5 (48 kg) 106.5 (48 kg)
Cooling
Natural Convection - Heat Sink
Relative Humidity
0% to 95% Condensing
Ambient Temperature Range
-15°F to 105°F (-25°C to 40°C)
Environmental Rating
NEMA 3R
Listings
UL 1741, IEEE 1547, IEEE 519, IEEE 929, IEEE 620,
CSA 22.2 107.1
GFI Fuse
Littlefuse KLKD1 1A/600VDC
Table A-1 Inverter PVP1100 through PVP2800 Specifications
SPECIFICA
TIONS