circuit from the batteries to the charger. They are located on the DC distribution panel. Push to reset the
breakers. The internal fuses in the charger protect the DC charging circuit from the charger to the batteries.
Outlets
Supply electrical current to the cabin ground fault interrupter (GFI) electrical outlets. All AC electrical outlets
are provided with ground fault interrupters to protect against electric shock. These outlets should be tested
periodically to ensure proper operation by pressing the test/reset buttons in the center of face plate. GFI outlets
do not protect against short circuits and overloads. This is done by the outlet breakers on the AC panel.
GFI OUTLETS DO NOT PROVIDE 100% PROTECTION FROM ELECTRIC SHOCK. EVEN
THOUGH GROUND FAULT INTERRUPTERS PROVIDE PROTECTION BY REDUCING EX-
POSURE TIME FROM LINE TO GROUND SHOCK HAZARDS, IT IS STILL POSSIBLE TO
RECEIVE AN ELECTRIC SHOCK FROM DEFECTIVE APPLIANCES OR POWER TOOLS AND
MISUSED ELECTRICAL EQUIPMENT.
Air Conditioner (Optional)
Supplies electrical current to the air conditioning control panel and the air conditioner raw water pump when
this option is installed. Otherwise it is reserved for additional AC equipment. This breaker will trip if sea
water is not being supplied to the air conditioning unit. If this breaker trips, reset and check for water flow
out of the air conditioning thru-hull. Refer to the air conditioner owner’s manual for additional information.
Water Heater
Supplies electrical current directly to the water heater circuit. The water temperature is automatically
controlled by a thermostat in the water heater control panel. Before operation, you must have water in the
water heater (see the water heater manual for more information).
4.5 Generator (Optional)
Your Pursuit may be equipped with an optional diesel generator. This generator is not equipped with a DC
charging system. Therefore, it is important to activate the battery charger to maintain the starting battery
(starboard engine battery) and the house battery whenever the generator is running. An owner operator's
manual for the generator has been supplied with this manual. Please refer to it for details on the generator
operation.
The generator is located in an enclosure in the aft bilge. The generator compartment is equipped with an
automatic fire extinguisher system and an automatic engine shutdown system. Refer to the Safety Equipment
chapter.
FUEL INJECTED GENERATORS REQUIRE BLEEDING OF AIR FROM THE FUEL DELIV-
ERY SYSTEM PRIOR TO INITIAL START-UP. BLEEDING OF THE FUEL SYSTEM WILL
ALSO BE REQUIRED IF THE GENERATOR IS ALLOWED TO RUN OUT OF FUEL. CON-
TINUED ATTEMPTS TO START THE GENERATOR WITHOUT BLEEDING THE FUEL SYS-
TEM UNDER THESE CIRCUMSTANCES CAN LEAD TO ENGINE DAMAGE OR ERRATIC
OPERATION. THIS PROCEDURE MUST BE COMPLETED BY YOUR SERVICING DEALER.
NOTICE
Summary of Contents for OS 315
Page 2: ...OS 315 2 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 4: ...OS 315 4 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 6: ...OS 315 6 OperatorNotes...
Page 8: ...OS 315 8 OperatorNotes...
Page 10: ...OS 315 10 OperatorNotes...
Page 58: ...OS 315 58 OperatorNotes...
Page 64: ...OS 315 64 OperatorNotes...
Page 74: ...OS 315 74 OperatorNotes...
Page 90: ...OS 315 90 OperatorNotes...
Page 98: ...OS 315 98 OperatorNotes...
Page 106: ...OS 315 106 OperatorNotes...
Page 114: ...OS 315 114 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 116: ...OS 315 116 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Page 117: ...OS 315 117 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Page 118: ...OS 315 118 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Page 119: ...OS 315 119 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Page 120: ...OS 315 120 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Page 124: ...OS 315 124 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Page 128: ...OS 315 128 THIS PAGE WAS LEFT BLANK INTENTIONALLY...