15
OPEN
7
8
9
6
10
CLOSED
Entrance
Prefiltration
CF
Membrane
RO
Postfiltration
CB
Glass
Probe
quality
CLOSED
OPEN
OPEN
OPEN
• Once the assembly is installed, keep the new manual
inlet valve closed and open the inlet valve connected to
the wall adapter (7). The measuring cup must be empty.
• Pour 0.25 liters of Hydrogen Peroxide into the dosing
glass interspersed at the entrance of the equipment (8).
Thread the glass correctly to its head.
• The manual inlet valve and the tap must be closed.
Connect the equipment to the electrical power supply.
• Open the water inlet faucet to the equipment and the
tap, allowing it to start its function and letting it suck
the Hydrogen Peroxide into it. Fill a 1L jug with tap wa-
ter. Before turning on the faucet, turn the inlet key back
on to lower the pressure. Refill the dispenser with 0.25l
of hydrogen peroxide and empty1 liter more water. Clo-
se the faucet. At this time the entire circuit contains
sanitizing liquid.
• After 10 mins. open the dispenser faucet (9) and let
mains water circulate for 5 mins.
• Empty the measuring cup. Before opening it, have a
container in your hand where you can empty it, as it
may be full of water.