5
WU-UV SERIES
| Filtration & Ultraviolet Disinfection All-in-One Unit
Installation Guide
Positioning Your System
Choose a location with a structurally appropriate mounting position. Allow a chamber
length space above the unit for removal of the lamp and sleeve from the Radfire UV
system during servicing and 120 mm below the housings for replacing the cartridges
and maintenance.
An isolation valve may be installed prior to the WU-UV system to isolate the unit for
changing the cartridges, lamps and sleeve.
To protect your WU-UV system make sure the site is frost free and has adequate
ventilation. Choose a location with adequate drainage and where water spillage will not
cause damage that may occur over time from leaking pipe joints or seals.
Power Surge Protection
An electrical power surge or spike can travel on the supply lines and cause serious
damage to your electrical equipment. The Radfire UV Electronic ballast has a fuse
(non-replaceable) to protect the circuit. The fuse is not a lightning arrester and may not
protect the Radfire if lightning or a very powerful surge hits the unit.
A suitable surge protection device must be installed with this product (not included).
Puretec recommends the use of a surge protector or warranty may be voided.
It would usually be sufficient for the surge protector to be installed under the
eaves of a house and/or out of the weather, otherwise, it would need to be suitably
protected. Ensuring the surge protector is suitibly protected from water/moisture is the
responsibility of the user. Alternatively a hard-wired outdoor surge protector my be
installed by a qualified electrican or an outdoor rated surge protector may also be used.
Order code for surge protectors: PC-SURGE (sold seperately)
Do not use long extension leads as they may cause substantial voltage drop and/or poor
lamp performance.
We recommend the use of an RCD or earth leakage circuit breaker
on the power
supply to your unit.
Summary of Contents for WU-UV Series