Cold/Ambient Water Commissioning
21. Turn on the water supply at the inlet (SmartTee™ valve).
22. Turn on the power supply at the power point -The tap light should illuminate.
23.
Flush the filters by pressing the cold button
on the tap for 1-2 minutes
followed by the ambient button
for another 1-2 minutes or until water runs
clear of carbon fines. (It is normal for black fines, cloudiness or micro-bubbles to come
through during the filter flush).
Note
: To activate water flow, press the button once and the ring light on the top of the
tap body will go green, then press and hold the button again for water flow.
24. Turn on the COLD power switch on the back of the chiller. The chilling indicator on the
front panel of the unit will turn off once the correct temperature is reached.
Note
: The temperature is preset to 4-10 degrees within the tank. It takes approx 20-
30 minutes to complete its chill cycle dependent on incoming water temperature and
ambient surrounds of the unit.
Soda/Sparking Water Commissioning
25. Ensure the CO
2
bottle is connected firmly to the regulator and the black gas tube is
fitted correctly.
26. Slowly open the CO
2
regulator by turning the black knob clockwise (+) until the gauge
reads 3 Bar.
27.
Turn off the water supply at the inlet (SmartTee
™
valve).
28. Purge the soda water line of any air by pressing on the sparkling button
on the
tap for 30 seconds.
29. Turn on the water supply at the inlet (SmartTee™ valve).
30. Turn on the SODA power switch on the back of the chiller and operate the sparkling
button
on the tap for 15 seconds allowing any excess CO
2
to be dispensed.
31.
Allow 2-5 minutes for the soda tank to fill completely.
Note:
The bar pressure on the CO
2
gauge will increase during this process. Venting
from the CO
2
gauge and/or the pressure relief valve within the unit is normal during
this step.