11
Copyright © Puretec Pty Ltd 2021
Puretec Sparq S4 User Guide
Installation
where any leakage could cause property damage, and/or the water supply should be
turned off if no one is home/present.
1.
Select a suitable position for the tap so that it dispenses into the sink bowl with ample
clearance below the outlet and drill a 26 mm hole (max 30 mm).
2.
Isolate water supply. Uninstall the connections on the cold water line and connect the
SmartTee™ (see Fig. 6). Reinstall the previous connection to the SmartTee™.
3.
Connect the inlet of the multivalve to the outlet of the SmartTee™ with a length of
blue tubing. Please see Fig. 4 for water flow direction.
4.
Connect the straight connector to the white tube on the tap (see Fig.4).
5.
Remove the black plastic nut from the tap thread and connect the wiring loom to the
tap (see Fig.4). Take care not to bend or break the pins.
6.
Carefully feed the straight adaptor, tap connections and wiring loom through the tap
hole and place tap into position ensuring it sits flush to the sink/benchtop.
7.
Screw the tap nut on and tighten making sure the tap is correctly positioned on top.
Fixing the tap to a sink may require more care to align all the parts. HAND TIGHTEN
ONLY. Do not overtighten as overtightening may split the plastic nut.
Note:
For thin bench tops or a sink mount, use the supplied spacer, slipping it up the
thread, followed by the black nut to tighten.
8.
Choose the best position for the unit with the required 150 mm clearance for
ventilation to the rear and top of the unit. Remember to allow access room for
changing filters at the top of the unit and a suitable place where water spillage will
not cause damage.
Note:
If cupboard does not permit enough space for filter changes, leave enough tube
length to allow the filter system to come out of the cupboard to change the filters.
Installation
VERY IMPORTANT!
The following installation sequence must be followed in the
correct order and as specified in this userguide by suitably qualified tradespeople.
The unit and CO2 Bottle must be installed upright (as depicted within this user
guide) In the event of a leak or electrical fault, the unit must be isolated from
both power and water. Advice should be sought out by the relevant licenced
tradesperson.
Installation Note
:
A water filter system/tap, like any product, has a limited life and may
eventually fail. Also sometimes failure happens early due to unforeseen circumstances.
To avoid possible property damage, this product should be regularly examined for
leakage and/or deterioration and replaced when necessary. A drain pan, plumbed to an
appropriate drain or outfitted with a leak detector, should be used in those applications