6.2 Before You Begin
6.2.1
Carefully inspect the unit, including the shipping box as well as the
Dehydrator for ANY DAMAGE CAUSED BY SHIPPING. If any
shipping damage is detected, it is important to file a claim with the
shipping company prior to continuing the installation procedures.
6.2.2
Read the entire
Installing Your Dehydrator
Section to familiarize yourself
with the components and procedures before performing the Dehydrator
installation.
6.2.3
Verify the installation location of the Dehydrator:
6.2.3.1
Well ventilated and free from abrasive dust or chemicals.
6.2.3.2
Ambient temperature is between 40° and 85° F (optimal).
NOTE:
Higher temperatures will decrease component lifespan.
6.2.3.3
Meets the following power requirements:
•
10 amp service recommended
•
24 VDC for P200W model (7 Amp slow blow fuse)
•
48 VDC for P208W model (7 amp slow blow fuse)
•
85 - 264 VAC, 1 Phase for P200WA model
(5 amp slow blow fuse)
6.2.4
Notify the alarm center of the installation and potential for alarms during
the process (if applicable).
6.2.5
If you are unable to complete any of the installation steps as described,
please refer to the Troubleshooting Your Dehydrator Section 11 for further
guidance.
WARNING!
DO NOT CONNECT THE DEHYDRATOR TO THE SUPPLY LINE
UNTIL THE HUMIDITY READING IS 5% OR LESS.