background image

06

07

3.3

“Coil Temp 000°C”: 

Used to display the current

temperature of the coil.When it is below zero,
the “-” symbol is displayed in front. “-” is not
required on zero.

3.4

Wifi hotspot: 

factory setting is “0FF”,

press > to enable wifi hotspot and switch
ON/OFF.The device can transmit data and receive
APP commands.The icon flickers when connected
on the main interface. After successful connection, .
the icon displays normally.

3.5.1

3.5.2

The power down time is adjusted according 
to “>” and the power down time increases 
from 3 to 20 minutes (3-5-10-15-20), which 
is the so-called stop time of the fan after 
shutdown, in order to better drain the 
water.Factory set for 3 minutes.(the other 
state of the fan is still 15 seconds.)

The screen displays when you 
press shut down:

Indicates: the fan is closed after 
a few minutes,and the standby 
page UNIT OFF is displayed after 
the fan is closed.

3.6

3.7

“Temp Units °F/°C”:

 Used for temperature 

scale switching. Press the “>” button to 
switch°F / °C,after switch symbol of 
corresponding parts is also changing.

“MOISTURE CONTENT UNITS”: 

It is used to switch the unit of GPP 
value with moisture content. 
Press > to switch the Ib or Kg, after
switch symbol of corresponding
parts is also changing.

4

5

3.8

“Humidistat Setpoint 00%”:

 Used for setting 

dehumidificationmode humidity.Press “>” to set the 
humidity. The adjustment range of humidity setting is 
between 25 and 80%.Each key rises or falls 5%, which 
can be recycled.

When the setting is completed,do not operate for 5 seconds
and begin to take effect.(Otherwise, the compressor will be
shut down immediately after it is below ambient humidity at the time of setting.) Humidity 
below 25 percents "CO" mode recyclable.' The main interface displays the set parameters.

MAIN INTERFACE FROSTING STATUS DISPLAY:

The machine will display this after defrost when running

When the machine is running normally, 
“Deffrost SHUTDOWN IN 06:00”will 
occurs in the interface after defrosting. 
It's defrost countdown use seconds as 
units. This screen displays only 3 
seconds. Displays the previous 
interface and status after restoration.lf 
it is the home screen,the frost icon 
will flash.

When the user is operating in the submenu, 
the machine is in the frosting state .At this 
point, the frosting interface displays 3 
seconds, and returns to the submenu 
program in the background countdown.
When the user returns to the main interface 
without any operation, the frosting state 
is displayed inthe main interface in the way 
of icon flicker.

COM PRESSOR ON WAITING INTERFACE DISPLAY

Compressor protection time not shown:

“Compressor ready IN 03:00” indicates :

 That the

interface will be displayed when the compression is
in a protected state. (including power-on and shutdown,
the humidity rises immediately after the arrival of LO
HI, and the shutdown resumesimmediately after the
emergence of LO HI). Displays the countdown in seconds.
If the above situation does not occur within 3 minutes, it is 
not shown.

PureAiro 

WCD 85C

Summary of Contents for WCD 85C

Page 1: ...SLGR Microchannel technology Condensate pump Quick easy connector for a drain tube Convenient storage for cable and drain tube Ducting option Automatic humidistat control PUREAIRO WCD 85C PureAiro sol...

Page 2: ...prevent any mold and mildew growth The WCD 85C dehumidi er is able to e ectively maintain the humidity levels in a space of up to 2 300 sq ft while maintaining comfort level as the unit will produce s...

Page 3: ...TO REDUCE RISK OF INJURY Always disconnect machine from electrical power before servicing Only plug unit into a gounded electrical cicuit Do not use an extension cord Do not use a plug adapter SAFETY...

Page 4: ...e total working time hours which is in hours press the mode key select the con rmation key and the total working time will be cleaned after 3 seconds IN OUT 00 F 00 00 GR LB Indicates the temperature...

Page 5: ...Each key rises or falls 5 which can be recycled When the setting is completed do not operate for 5 seconds and begin to take e ect Otherwise the compressor will be shut down immediately after it is b...

Page 6: ...he interface cannot be operated The pump button an be operated Ambient temperature T 45 When the sensor continuously detects the inlet air environment temperature T 45 degrees for 15 seconds the fault...

Page 7: ...ASE PureAiro warrants the compressor condenser and evaporator will operate free of any defects in material or workmanship At it s discretion PureAiro will repair or replace the defective parts This do...

Page 8: ...e price of the product if a product or component is replaced while under warranty the applicable warranty period shall not be extended beyond the original warranty time period After parts are repaired...

Reviews: