Parts Breakdown — Buv Models

Item #

Part Ref

Description

Qty

For UV Model

89573

2

Quartz Sleeve, Buv-6

1

Buv-6

89574

2

Quartz Sleeve, Buv-8

1

Buv-8

89575

2

Quartz Sleeve, Buv-12

1

Buv-12

89577

3

Chamber Nut, Lamp Entry, Threaded

2

All Models

89578

5

O-Ring

2

All Models

89584

6

Countdown Timer, c/w Bracket

1

All Models

89579

7

Clip

2

All Models

89581

8

Flow Control, 6 GPM, 1/2” NPT

1

Buv-6

89582

8

Flow Control, 8 GPM, 3/4” NPT

1

Buv-8

89583

8

Flow Control, 12 GPM, 1” NPT

1

Buv-12

89570

9

Lamp, UV, Buv-6

1

Buv-6

89571

9

Lamp, UV, Buv-8

1

Buv-8

89572

9

Lamp, UV, Buv-12

1

Buv-12

89580

10

Ballast

1

All Models

89576

11

Strain relief

1

All Models

89585

12

Chamber Nut, c/w Stopper Bottom

1

All Models

Item #

8880

8881

8882

Model #

Buv-6

Buv-8

Buv-12

Supplier Item #

GN-6

GN-8

GN-12

NSF Rated Flow Rate @ 16mJ/

cm2 @ 70% UVT - usgpm (l/min)

5.5 (20.79)

7.8 (29.48)

12 (45.36)

Inlet and Outlet Size NPT

1/2”

3/4”

1”

Operating Pressure psi (kpa)

10-100 psi (69-689 kPa)

Operating Temperature Range

36 to 104° F (2 to 40° C)

Electrical

100-240V - 50/60Hz

Performance Data Sheet

While testing was performed under standard laboratory conditions, actual performance may vary.
This Class B system or component conforms to NSF/ANSI 55 for the supplemental bactericidal treatment disinfected public 

drinking water or other drinking water that has been tested and deemed acceptable for human consumption by the state or local 

health agency having jurisdiction. The system is only designed to reduce normally occuring non-pathogenic nuisance microorgan-

isms. Class B systems are not intended for treatment of contaminated water.
The system and installation shall comply with applicable state and local regulations

   Lamp life: 8000-9000 hours of operation approximate 

12 months of continuous service

   General installation conditions and needs: Avoid touch-

ing the sides of the quartz sleeve and lamp, handle by 

the ends only. Ultraviolet lamp and quartz sleeve are 

easily damaged.

    General operation and maintenance: Quartz sleeve is 

to be cleaned every 6-12 months and to be replaced 

every 24 months. UV lamp is to be replaced every year. 

1

1

9

3

11

10

2

8

5

12

7

6

5

4

5

System Tested and Certified by 

NSF International against NSF/

ANSI Standard 55 for Disinfection 

Performance, Class B

Summary of Contents for Buv-12

Page 1: ...UAL OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System Buv 6 Buv 8 Buv 12 55003 0612 System Tested and Certified by NSF International against NSF ANSI Standard 55 for Disinfection Per...

Page 2: ...bled and they are unable to reproduce Since the cell is now sterile or dead it is no longer a threat PURA Systems PURA recommends that all UV systems include pre filters to process the water before it...

Page 3: ...nd warnings on the water disinfection system 10 If an extension cord is necessary a cord with a proper rating should be used A cord rated for less Amperes or Watts than the disinfection system rating...

Page 4: ...that may be used for the installation Routine Maintenance It is important that any water treatment system be properly maintained to ensure consistent water quality The information provided on this pag...

Page 5: ...I make sure that this is taken into consideration prior to any installation The system can either be installed vertically inlet port at the bottom Figure 1A or horizontally Figure 1B When selecting a...

Page 6: ...ter from potentially entering the controller 5 Install the UV lamp and sleeve as outlined on pages 8 9 6 When all plumbing connections are made slowly turn on the water supply and check for leaks The...

Page 7: ...the locations have passed the chlorine disinfection solution you will need to leave the solution sit for a period of 20 30 minutes Reinstall the pre filter cartridge into the filter and then flush the...

Page 8: ...er being careful not to angle the lamp as it is removed from the chamber If the lamp is removed on an angle pressure will be applied on the inside of the quartz sleeve causing the sleeve to fracture S...

Page 9: ...ction on page 8 9 Slowly turn on the water and pressurize the reactor to verify that there are no leaks 10 Reconnect to power source NOTE If the system is put on a temporary bypass or if it becomes co...

Page 10: ...system 3 Heated Product Water A Common problem caused by infre quent use of water A Run water until it returns to ambient tempera ture 4 Water Appears Milky A Caused by air in the water lines A Run w...

Page 11: ...ance Data Sheet While testing was performed under standard laboratory conditions actual performance may vary This Class B system or component conforms to NSF ANSI 55 for the supplemental bactericidal...

Page 12: ...rranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PROD...

Reviews: