Model PW513
X-10 to UPB Bridge
Installation Guide and
Owner’s Manual
The Inventors Of:
19215 Parthenia St. Suite D
Northridge, CA 91324
P: 818-701-9831
FUNCTION
The X10 to UPB Bridge (model
PW513) is a plug-in home
automation interface that is
capable of receiving X-10
messages from a standard (PL-
513) 4-wire cable and
transmitting their corresponding
Universal Powerline Bus (UPB)
messages onto the power wiring
to remotely turn on, off, and dim
other UPB devices. The PW513
can be freely located anywhere a wall outlet exists throughout
the home. No additional wiring is required and no radio
frequency signals are used for communication.
FEATURES:
•
Simple plug-in installation.
•
Adds UPB ultra reliability to any X-10 compatible
controller.
•
Converts A-1 thru P-15 to UPB Links 1-255.
•
Flexible configuration of command mapping.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions
should always be followed, including the following:
1.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.
Keep away from water. If the product comes in contact
with water or other liquid, turn off the circuit breaker and
unplug the product immediately.
3.
Never use products that have been dropped or damaged.
4.
Do not use this product outdoors. Do not use this product
for other than its intended purpose.
5.
Do not cover this product with any material when in use.
6.
This product uses grounded plugs and sockets to reduce
the risk of electric shock. These plugs and sockets fit only
one way. If they do not fit, consult an electrician.
7.
SAVE THESE INSTRUCTIONS.
INSTALLATION
The PW513 is designed for indoor use with devices that plug
into a grounded power outlet. To install the PW513 module:
1.
Locate any free wall outlet near your X-10 controller.
2.
Plug the PW513 into the wall outlet (see illustration).
3.
Optionally, the device can be secured to the wall outlet
by screwing the wall plate center screw through the
device’s mounting tab.
4.
Use a pass through telephone type cable to connect the
PW513 to your X-10 controller or alarm panel.
Wall
Outlet
Program
Button
Status
LED
OPERATION
Once installed and configured your PW513 will operate on the
stored configuration settings without further user intervention.
All programmed data is protected by nonvolatile memory and can
only be changed or deleted by reprogramming, regardless of
power outage durations.
Device Code Mapping
In the X-10 world devices are selected to be operated upon using
the Device Code Message. The Device Code Message contains two
fields: the X-10 House Code (A – P), and the X-10 Unit Code (1 –
16) that are intended to identify a device (or set of devices) to act
upon the upcoming Function Code message. In the UPB world
devices are selected to be operated upon using the Link ID. Link
IDs can range from 0 to 255 and they are intended to identify a
device (or set of devices) to act upon the upcoming Message Data.
Note:
All PulseWorx™ dimmers come from the factory assigned
with Link IDs 1 – 6 & 8. All PulseWorx™ switches come from the
factory assigned with Link IDs 1 and 2.
The PW513 uses the received X-10 Device Code Message to map
to a UPB Link ID as shown in Table 1 below.
X-10 Device Codes
UPB Link IDs
A1 – A16
1 – 16
B1 – B16
17 – 32
C1 – C16
33 – 48
D1 – D16
49 – 64
E1 – E16
65 – 80
F1 – F16
81 – 96
G1 – G16
97 – 112
H1 – H16
113 – 128
I1 – I16
129 – 144
J1 – J16
145 – 160
K1 – K16
161 – 176
L1 – L16
177 – 192
M1 – M16
193 – 208
N1 – N16
209 – 224
O1 – O16
225 – 240
P1 – P15
241 – 255
P16
0