Model: FMR1
Fixture Module - Relay
Installation Guide and
Owner’s Manual
FUNCTION
The FMR1 Fixture Module - Relay is a high quality wire-in
home automation load controller that is capable of turning
120VAC appliances and fluorescent lamps ON and OFF based
on digital commands received over the power wiring from a
remote UPB (Universal Powerline Bus) controller. UPB
controllers and modules can be freely located anywhere
throughout the home. No additional wiring is required and
no radio frequency signals are used for communication.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions
should always be followed, including the following:
1.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.
Keep away from water. If the product comes in contact
with water or other liquid, turn off the circuit breaker and
unplug the product immediately.
3.
Never use products that have been dropped or
damaged.
4.
Do not use this product outdoors.
5.
Do not use this product for other than its intended
purpose.
6.
Do not connect multiple lamps or appliances that, when
combined, exceed the maximum load ratings of the
product.
7.
To avoid any risk of fire, burns, personal injury or electric
shock, install this product out of the reach of small
children.
8.
Do not cover this product with any material when in use.
9.
This product uses grounded plugs and sockets to reduce
the risk of electric shock. These plugs and sockets fit only
one way. If they do not fit, consult an electrician.
10.
SAVE THESE INSTRUCTIONS.
INSTALLATION
The Fixture Module – Relay is designed for indoor use with
devices that are permanently wired into the home electrical
system. To install the FMR1 module:
1.
Locate the device to be controlled. Note that the device
power rating must not exceed 20 amps.
2.
Disconnect power at the circuit breaker.
3.
Remove any existing ceiling or wall fixture hardware for the
device. Disconnect the black wire that supplies power to
the device.
4.
Using a wire nut, connect the
black
(Line) wire of the
fixture module to the
black
(Line) power wire.
5.
Using a wire nut, connect the
red
(load output) wire of the
fixture module to the
black
wire from the lighting fixture or
device being controlled.
6.
Using a large wire nut, connect the
white
(Neutral) wire of
the fixture module to the
white
(Neutral) power wire and
the
white
wire from the lighting fixture.
7.
Refer to instructions on CONFUGRATION and OPERATION
prior to placing the fixture module in its final location, as it
may be necessary to have access to the Program Switch in
order to add the module to the UPB network and test its
operation. Temporarily restore power in order to perform
these functions. Disconnect power again when finished.
8.
Once proper operation is established, fit the module into
the outlet box or otherwise secure it using wire ties or
fitting the nipple into a ½” knockout. Reinstall fixture
hardware as needed.
CAUTION
: Do not insert metal objects into the module while it is
connected to power.
Program
Button
Status
LED
BLK
WHT
RED
BLK
WHT
Fixture
LINE
NEUT
120VAC
POWER
The Inventors Of:
19201 Parthenia St. Suite J
Northridge, CA 91324
(Phone) 818-701-9831 (Fax) 818-701-1506