background image

8

ASSEMBLY

Unpacking

1. Place box on a level surface.

2. Remove all items from box except the generator.  Make sure all items listed on the packing list are included and not

damaged.

3. Cut down the sides of the box being careful to avoid hitting the generator.

Packing List

Check all loose parts to the following list. Contact your dealer if any loose parts are not included.

Description

Qty

Generator

1

Operator's manual

1

Toolkit

       

Spark Plug Wrench

Funnel

1

(

)

1

Product registration card

1

• Place generator on a level surface.

Remove the crankcase dipstick to ensure you do not overfill the engine.

Insert a funnel into the crankcase dipstick hold and carefully add 4-Cycle engine oil (SAE10W- 30) to empty reservoir

until oil reaches the outer edge of the oil fill hole (crankcase dipstick hole).

• Be sure to replace dipstick before attempting to start the engine.

• To check oil, set generator on a level surface, wipe dipstick clean, then reinsert dipstick without rethreading.

Adding / Checking Engine Oil (See fig 

1

)

You must add oil before first operating this generator. Always check oil level before each 

operation.
DO NOT USE E15 OR E85 FUEL IN THIS UNIT. IT IS A VIOLATION OF FEDERAL LAW AND 

WILL DAMAGE THE UNIT AND VOID YOUR WARRANTY.

CAUTION!

Fig 

2

Gasoline

Unleaded 

Fig 

1

10W30 OIL

Summary of Contents for G465GN

Page 1: ...Generator Model G465GN www pulsar products com OPERATOR S MANUAL ...

Page 2: ...0 Connecting Generator to an Electrical System 10 Operation 11 How to Start Engine 11 Grounding the Generator 11 How to Stop Engine 12 Receptacles and Extension Cords 13 Don t Overload Generator 14 Wattage Reference Guide 15 Cold Weather Operation 16 Maintenance 17 Maintenance Schedule 17 Engine Maintenance 18 Changing Oil 18 How to Store 20 Troubleshooting 21 Diagrams 22 Warranty 23 TABLE OF CONT...

Page 3: ... Wattage 3600W 3 6kW Rated Voltage 120V 240V Rated Frequency 60Hz Rated Ampere 30A 15A Maximum Output 4 65kVA The emissions control system for this generator is compliant with all standards set by the Environmental Protection Agency How to contact us To order parts receive warranty assistance or other services inquiries you can contact us by internet at www pulsar products com or write to us at PU...

Page 4: ...f serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting Never use indoors in a covered area or in a confined space even if doors and windows are open Keep exhaust from this unit from entering a confined area t...

Page 5: ... If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve turned to the off position WARNING Never exceed generator s wattage amperage capacity This could damage the generator...

Page 6: ...r will supply the correct rated frequency and voltage WARNING Never modify this unit in any way or modify governed speed Never handle the generator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Use a ground fault circuit interrupter GFCI in a damp or highly co...

Page 7: ...ik L Recoil Starter Grip M Fuel Valve ON OFF N Choke Level O ON OFF Start Switch P Oil Alert A Fuel Tank Vapor Vent B Fuel Fill Cap C Fuel Tank D 2 120V Receptacles E Circuit Protector F 120V 240V 30Amp Twist Lock G Voltage Selector Switch H 120V 30Amp RV O P ...

Page 8: ...nkcase dipstick to ensure you do not overfill the engine Insert a funnel into the crankcase dipstick hold and carefully add 4 Cycle engine oil SAE10W 30 to empty reservoir until oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick before attempting to start the engine To check oil set generator on a level surface wipe dipstick clean then reinsert dips...

Page 9: ... serious injury or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System a transfer switch The power from the generator must be isolated from the circuit breaker or alternative power source If connecting generator to a building s electrical system...

Page 10: ... must always be used to connect generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AWG American Wire Gauge copper wire The wire connects to the terminal between the lock washer and nut Tighten the nut securely to ensure proper connection Grounding the generator protects you from electric shock that results from a build up of static electricity or unde...

Page 11: ...Never start or stop the engine with electrical devices plugged in to the receptacles Turn the fuel valve to the OFF position Turn the engine ON OFF switch to the OFF position Fig 8 Fig 9 Fig 10 2 Fig 4 Fig 5 CHOKE RUN CHOKE LEVER Fig 6 Recoil Start Fig 7 ON OFF 1 2 CHOKE RUN CHOKE LEVER WAIT 5sec ...

Page 12: ...0 ft 200 ft 125 ft 100 ft 10 1200 2400 X 250 ft 150 ft 100 ft 50 ft 15 1800 3800 X 150 ft 100 ft 65 ft X 20 2400 4800 175 ft 125 ft 75 ft X X 25 3000 6000 150 ft 100 ft X X X 30 3600 7200 125 ft 65 ft X X X 120 Volt AC 20 Amp receptacle Two 120 Volt AC 20 Amp receptacles One 120 Volt AC 30Amp RV receptacle 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 This receptacle has a 20 Amp push t...

Page 13: ...your back to avoid injury Don t Overload Generator Make sure you can supply enough rated watts and surge watts for all electronic devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the power a generator must supply to start an electronic device This power surge for starting a device usually lasts between 2 3 secon...

Page 14: ...00 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000 Electric Blanket 400 400 Space Heater 1800 1800 Kitchen Blender 300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric Range 1 element 1500 1500 Dishwasher 1500 3000 Electric Oven 3410 3410 Electr...

Page 15: ...e section of manual 5 Shelter unit from elements OPERATION 15 High Altitude Operation At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and fuel consumption will increase A very rich mixture will also foul the spark plug and cause hard starting Operation at an altitude that differs from that at which this engine was certified for extended periods ...

Page 16: ...e sure the air filter is clean Remove any debris that has collected on the generator and around the muffler and controls Use a vacuum cleaner to pick up loose debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Store unit in a clean and dry area WARNING After First 5 Hours Change Oil Afte...

Page 17: ...oil to drain completely Reinstall oil drainage plug tighten securely To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter annually Reinstall air filter so that it seals and replace air filter cover Air Filter See Fig 12 A dirty air filter will reduce the life span...

Page 18: ...ilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor Store indoors and use a protective cover to protect from dust Draining the fuel tank Turn the engine OFF Turn the fuel valve to the OFF position Push the fuel valve knob through the valve holder bracket allowing you to access the petcock Remove the fuel line that leads to the carburetor from the petco...

Page 19: ...ter in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded 1 Turn switch to ON 2 Replace Air filter 3 Clean or replace fuel filter 4 Replace fuel 5 Reconnect spark plug wire 6 Replace spark plug 7 Drain fuel tank and replace fuel 8 Turn fuel valve to ON pos...

Page 20: ...DIAGRAMS 20 ...

Page 21: ...ator engine and alternator components parts and labor Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial construction or other income producing purposes Once a generator has been used for commercial purposes it shall thereafter be considered as a commercial use generator for the purposes of this ...

Page 22: ... the United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under this warranty Products used for commercial use are not covered under this warranty How to Obtain Warranty Service Take the original receipt and product to the place of purchase or mail the original re...