PULSAR MEASUREMENT
49
P950 Save Trace on LOE
The dBi-M series intelligent transducer stores an echo trace internally when
the LOE (Loss of Echo) condition is triggered. When requesting an echo
trace the LOE trace will be displayed on the graph. This parameter sets the
frequency at which a trace is saved to the dBi-
M’s internal memory in a LOE
condition.
OPTION
DESCRIPTION
0 = Off
Trace mode is turned off.
1 = Once
When the dBi-M goes into LOE, the dBi-M will
save the first trace in its internal memory.
2 = Repeatedly
When the dBi-M goes into LOE, the dBi-M will
save the trace in its internal memory overwriting
the previous trace for the new one.
Datem
P20 Reset Datem
This parameter allows the DATEM to be reset to its default value, just
DATEM points or alternatively allow the user to perfo
rm a ‘blank tank’. It
should be noted that when using the ‘blank tank’ option, all echoes will be
eliminated by DATEM.
OPTION
DESCRIPTION
0 = Off
Trace mode is turned off.
1 = Once
When an alarm condition is activated, the dBi-M
will save the first trace in its internal memory.
2 = Repeatedly
When an alarm condition is activated, the dBi-M
will save the trace in its internal memory
overwriting the previous trace for the new one.