Nazwa/ Name: 

17/40/S-F

/

PUSTA

 

Obudowa metalowa do: SSWiN, KD,…. 

Metal casing for: alarms, access control....

 

                                                                                                                                       

IM500PU

     

 

 

                                                                                                             

                                                                                                                 

 

Wydanie: 3 z dnia 18.10.2017  

                                                                                                   Zastępuje wydanie: 2 z dnia 09.01.2017 

            

                                                                                                                                  

PL 

 

1. Przeznaczenie:

 

 

Obudowy 

AWO 500PU

 zaprojektowane zostały jako elementy systemów SSWiN, KD, itp.  

Przeznaczone są do montażu (w zależności od modelu):  

 

płyty centrali alarmowej i opcjonalnie dodatkowych modułów 

 

kontrolera systemu KD i modułów dodatkowych 

 

nadajnika radiowego lub GSM, opcjonalnie modułu zasilacza buforowego  

 

innych dedykowanych urządzeń 

 

do obudowy można zamontować transformator typu: TRZ40, TRZ50, TRZ80. 

 

2. Montaż:

  

 

Obudowa przeznaczona jest do montażu przez wykwalifikowanego instalatora, posiadającego odpowiednie          

(wymagane i konieczne dla danego kraju) zezwolenia i uprawnienia do ingerencji w instalacje niskonapięciowe. 

Obudowa (+PCB) powinna być montowana w pomieszczeniach zamkniętych, o normalnej wilgotności powietrza 

(RH=90% maks. bez kondensacji) i temperaturze z zakresu -10°C do +40°C. 

 

 

 
 

 
 
 

 
 

1. Destination: 

EN 

 

The 

AWO 500PU

 metal casings are designed as components (supplying) in intruders alarms, access control 

systems, security systems etc. There are intended for installation: 

 

control panel optional with supplementary modules 

 

access control controllers with optional modules  

 

radio or GSM transmitter with optional module PSU 

 

other dedicated devices, components etc. 

 

transformers which can be mounted in the casing: TRZ40, TRZ50, TRZ80. 

 

 
2. Installation:  

 

 
The metal casing must be installed by a qualified installer, holding the relevant certificates, required and 

necessary in the particular country for connecting (interfering with) the 230V AC systems and low-voltage installations.  

The casing (+PCB) should be installed indoors, where the air humidity is normal (RH=90% max. without 

condensation) and temperature in the range of -10°C to +40°C. 

 

 

 
 
 

 

Summary of Contents for AWO 500PU

Page 1: ...ingerencji w instalacje niskonapięciowe Obudowa PCB powinna być montowana w pomieszczeniach zamkniętych o normalnej wilgotności powietrza RH 90 maks bez kondensacji i temperaturze z zakresu 10 C do 40 C 1 Destination EN The AWO 500PU metal casings are designed as components supplying in intruders alarms access control systems security systems etc There are intended for installation control panel o...

Page 2: ...rmers which can be mounted in the casing KOD CODE NAZWA NAME C S U I U1 lub U2 lub U3 or or I1 lub I2 lub I3 or or F t AWT468 TRZ 40 16 18 PC ABS UL94 V 0 IP43 40VA 230V AC 0 20A 16V lub 18V or 2 2A lub 2 0A or T 315mA 250V 130 o C AWT 5161820 TRZ 50 16 18 20 PC ABS UL94 V 0 IP43 50VA 230V AC 0 25A 16V lub 18V lub 20V or or 3 0A lub 2 8A lub 2 5A or or T 500mA 250V 130 o C AWT 5172430 TRZ 50 17 24...

Page 3: ...SM PYRONIX 1 MATRIX 424 6 816 832 832 CROW 1 RUNNER 4 8 TELMOR 1 TCA 824 ROEL SIGMA 6 12 CERBER ROGER 1 PR402 CPR 32 SE EBS 1 PX 202A PULSAR 1 MS1012 MSR1012 MSRK1012 2 MS2012 MSR2012 MSRK2012 Blacha Mounting plate 500B 17 40 220 17 Ah DSC 1 PC1616 1832 1864 4020 5108 4108 5208 5100 4116 Moduły modules PC5204 5400 5580 5200 4216 4204 5108 5208 4108 5100 4116 PARADOX 1 E55 65 728ULT SP4000 SP5500 6...

Page 4: ...rtowych i detalicznych tego sprzętu oraz gminne jednostki organizacyjne prowadzące działalność w zakresie odbierania odpadów Prawidłowa realizacja tych obowiązków ma znaczenie zwłaszcza w przypadku gdy w zużytym sprzęcie znajdują się składniki niebezpieczne które mają negatywny wpływ na środowisko i zdrowie ludzi WEEE MARK The waste electric and electronic products do not mix with general househol...

Reviews: