UF40.241
UF-Series
24V,
40A,
160
MS
,
B
UFFER
M
ODULE
1.
I
NTENDED
U
SE
This device is designed for installation in an enclosure. Use an appropriate enclosure which protects against
mechanical, electrical and fire hazards.
This device is intended for professional use in areas such as in industrial control, office, communication, and
instrumentation equipment.
Do not use this device in equipment or systems where malfunction may cause severe personal injury or threaten
human life.
2.
I
NSTALLATION
N
OTES
This device may only be installed and put into operation by qualified personnel.
This device does not contain serviceable parts or fuses.
If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to
the factory for inspection.
The unit must be powered from a SELV source (according to IEC 60950-1), PELV source (according to IEC 62477-1) or an
Isolated Secondary Circuit (according to UL 508) power source.
Use DIN-rails according to EN 60715 with a height of 7.5 or 15mm.
Mounting orientation must be power terminals on top of the unit.
Do not obstruct air flow as the unit is convection cooled. Ventilation grid must be kept free of any obstructions.
Signal lines (ready, active and inhibit) must be shorter than 30m.
Use an appropriately sized power supply, which can deliver the additional required internal current consumption
(including the charging current) specified as input current in the table of chapter 4 and Fig. 4-1.
The following installation clearances must be maintained:
- Left / right: 0mm
- On top of the unit: 40mm
- On bottom of the unit: 20mm
Agency approvals apply only for altitudes up to 2000m.
Maximum surrounding air temperature: +70°C / +158°F.
Caution for Canada: For use in a controlled environment according to CSA 22.2 No 107.1-01.
WARNING
Risk of electrical shock, fire, personal injury or death.
- Turn power off before working on the device. Protect against inadvertent re-powering.
- Make sure that the wiring is correct by following all local and national codes.
- Do not modify or repair the unit.
- Do not open the unit as dangerous voltages may be present inside.
- Use caution to prevent any foreign objects from entering the housing.
- Do not use in wet locations or in areas where moisture or condensation can be expected.
- Do not touch during power-on, and immediately after power-off. Hot surfaces may cause burns.
Oct. 2016 / Rev. 1.0 DS-UF40.241-EN
All parameters are specified at 24V, 40A, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
3/18