TM-1300

 

Progressive Scan High Resolution Camera

 

Operations Manual

 

69-0048

Rev. A

Summary of Contents for TM-1300

Page 1: ...TM 1300 Progressive Scan High Resolution Camera Operations Manual 69 0048 Rev A...

Page 2: ...te maintenance and use Certifications UL CE FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are de...

Page 3: ...9 Connectors and Cables 10 3 OPERATION 11 3 1 Modes of Operation 11 3 1 1 Shutter Control Switch 11 3 1 2 Asynchronous Shutter 13 3 1 3 Frame Memory Memory Output Mode 14 3 1 4 Video Output 15 3 1 5 M...

Page 4: ...ns 31 5 1 2 Physical Dimensions 32 5 1 3 Glass Specifications 33 5 1 4 C Mount Specifications 33 5 1 5 Front End Detail 34 5 2 Spectral Response 35 5 3 Block Diagram 36 5 4 Digital Cable Assembly 37 5...

Page 5: ...9 Normal Mode vs Fast Dump Mode 19 FIGURE 10 Line Data Valid 20 FIGURE 11 Frame Data Valid 20 FIGURE 12 Pixel Clock 21 FIGURE 13 TM 1300 Camera Control Commands 25 FIGURE 14 Signal Board top side 26 F...

Page 6: ...rement High speed electronic shutter capability results in high dynamic resolution of moving objects Progressive scanning eliminates interlace deterioration of image High sensitivity and low noise at...

Page 7: ...tputs analog signals from the SVGA and BNC connectors The analog signal is processed in the camera for scan conversion in order to output high frame rate video SVGA The analog outputs are not recommen...

Page 8: ...Configuration Note Additional cable interface may be required from the frame grabber board manufacturer SVGA Monitor Frame Grabber Board Multi Sync Analog Monitor SHUTTER MODE UP DWN VIDEO POWER 0 1 2...

Page 9: ...e bench tested to assure that everything is fully operational as a system 2 1 2 Components List Please begin by checking your order against the Components List below to assure that you have received e...

Page 10: ...e connector 2 2 1 c Digital Output Connector An EIA 422 digital output is available from the 31 pin high rel micro miniature connector Airborn MP221 031 243 2200 The mating connector can be firmly sec...

Page 11: ...e sec 20MHz Analog 12 frame sec no display mode 6 A D Vref top Up Down 7 A D Vref bottom Up Down 8 Freeze ENINT enable Up Real time Down Freeze 9 Factory default recall Up Down Recall factory default...

Page 12: ...PD 12 power supply can be connected to the PULNiX power cable via a terminal strip or directly If wiring the PD 12 power supply directly please note the following Twist the lead ends together and tin...

Page 13: ...wer Cables If you are building your own power cables consult the pin out for the camera purchased and connect the Ground and 12V power leads of the PC 12P power connector to Pin 1 and Pin 2 respective...

Page 14: ...embly back and forth until the best image is obtained Tighten the focus ring set screws Your backfocus is now set 2 2 7 Auto Iris Lens Setup Auto iris lenses with full video input can be used with the...

Page 15: ...born P N MP211 031 113 3400 Straight Backshell cover PULNiX Part No 15 1625 Airborn P N MM253 031 000 4300 Cable assembly Digital cable 30DG 02 50 1301 01 8 bit standard cable or 30DG 02 40 50 1224 10...

Page 16: ...High state 5V with the dial switch set from1 to 9 the TM 1300 asynchronous camera discharges the photo charges into the substrate drain although the camera is still running on its sync timing and only...

Page 17: ...VINIT is generated at the leading edge negative going edge of the external trigger pulse Internal timing including the video sync is reset The shutter speed is the same as in manual shutter mode One f...

Page 18: ...m a frame buffer The frame buffer is updated with each new image captured upon receiving the next negative reset pulse Since the internal frame buffer is designed to capture asynchronously triggered i...

Page 19: ...ory keeps the stored image until the next image is completed so that there is no blank interval during integration 3 Digital format of the video output can be used as a direct interface with the compu...

Page 20: ...TV resolution of 1000 lines a monitor display may not be able to show 1000 lines due to monitor resolution and interlace scanning of the analog output The interline transfer architecture is also impo...

Page 21: ...ync Manual Shutter Selection The electronic shutter mode is selected by up manual and down async switch When it is in manual mode the shutter speed is programmed by the shutter speed switch When the a...

Page 22: ...frame rate of both digital and analog is 12 frame sec no SVGA output 3 1 5 f 6 and 7 A D Reference Voltage Control The CCD output itself has over 60 dB of dynamic range However the signal normally us...

Page 23: ...er Default Page This page is a default page for camera start up When camera is powered up it starts operating with the parameters stored in page A except switch positions of 9 factory set B through D...

Page 24: ...rmat 100 output termination impedance Output from 31 pin connector The mating connector Airborne MP211 031 113 4300 Please consult PULNiX digital cable information 50 1224 30DG 02 40 10 bit 2m cable 3...

Page 25: ...e data During integration both LDV and FDV are kept low and restart upon the completion of integration FIGURE 11 Frame Data Valid 3 1 6 d Pixel Clock Differential line driven signal with EIA 422 forma...

Page 26: ...and is then followed by the Command Code C C one alphabet Command option parameter and CR End of Text 0DH to end When a packet is received by the TM 1300 ETX 03H is detected it reads the internal pac...

Page 27: ...t Shutter Mode SX 1A0 CR 3AH 53H 58H 31H 41H 30H 0DH This selects a mode for external shutter speed control Hexadecimal shutter number 3 digit follows SX command e g 1A0 416H shutter speed 1050 416 63...

Page 28: ...d W Function Write data to the selected pages or calibration data table Saving to page from 9 through F W A F CR 3AH 57H 41H 46H 0DH Page 9 is factory use only Saving to calibration table WU command W...

Page 29: ...se is ACK S A D data 6 bytes For detailed parameters please contact PULNiX 3 1 7 j Command D Fast Dump mode D 1 CR 3AH 44H 31H 0DH Normal mode F 0 CR 3AH 44H 30H 0DH 3 1 7 k Command C Gain control Dir...

Page 30: ...000 400 Hex lines 2 G Gain 00 FF ACK 3 V A D Vref 00 FF Top 00 FF Bottom ACK 4 W Write P Page 9 F ACK U User A D S System A D 5 L Load P Page 9 F ACK U User A D S System A D 6 R Report R Current ACK...

Page 31: ...22 dB Jumpers W1 Gamma Set to 1 0 OFF W2 Clk enable Open W3 Not used W4 W7 for chassis GND FIGURE 14 Signal Board top side Bit 7 N A Bit 6 Freeze Flag 1 0 Bit 5 Async Mode Flag 1 0 Bit 4 N A Bit 3 Di...

Page 32: ...Select internal jumper W7 through W11 back side for power supply optimization Potentiometer VR1 PED Set pedestal at 50 mV of video analog 3 2 4 Memory Board Middle Board Bottom Side Preset VR1 D A re...

Page 33: ...OPERATION Page 28 TM 1300 Progressive Scanning High Resolution Camera FIGURE 16 Memory Board bottom W6 W7 W8 W9 J5 1 9 10 18 VR1 J10 W5 W3 W1 W2 J6 1 2 31 32...

Page 34: ...wing are properly connected and operational Power supplies Power cables Main power source Shutter control Async mode Lens 4 1 2 Symptom Dark Video Remedies Check that the following are properly connec...

Page 35: ...d Support Resources For further information and support Phone 408 747 0300 800 445 5444 800 3 PULNIX 24 hour message access Fax 408 747 0660 E mail pulnixapps aol com Mail PULNiX America Inc Sales Dep...

Page 36: ...V Digital 1300 H x 1030 V Video output Analog 1 0 Vp p composite video 75 sync negative SVGA 1 0 Vp p Video only RGB channels Sync TTL Video output Digital 10 bit 8 bit RS 422 differential output Dat...

Page 37: ...imensions FIGURE 17 Physical Dimensions 152 0mm 162 0mm PULNiX PROGRESSIVE SCAN 40 0mm 70 0mm 40 0mm 65 0mm 20 0 12 0 24 6 c L A A A B B B 3xO 25 20 UNC 2B 3xM6x1 0 A B 67 0mm 0 1 2 3 4 5 6 7 8 9 B A...

Page 38: ...Flange Back Length of the CS Mount is 12 5mm versus 17 526 of the C Mount The shorter Flange Back Length of the CS Mount allows room for the stripe filter incorporated in the color camera Additionally...

Page 39: ...ive Scanning High Resolution Camera FIGURE 20 Combination With CS Mount Camera 5 1 5 Front End Detail FIGURE 21 TM 1300 Imager Location C Mount Lens CS Mount Lens Focal Point 5mm Extension Ring 5 12 5...

Page 40: ...2 Spectral Response FIGURE 23 Spectral Response PIN 1 2X MOUNTING HARDWARE I C GASKET FILTER C MOUNT RING FRONT END 3X C MOUNT RING LOCKING SET SCREW Wave Length nm TM 1300 SPECTRAL RESPONSE 300 400 5...

Page 41: ...36 TM 1300 Progressive Scanning High Resolution Camera 5 3 Block Diagram FIGURE 24 TM 1300 Block Diagram CCD CDS Amp A D Timing Async CPU Sync Gen Memory Control D A Sync Add Mem Video RS 422 10 bits...

Page 42: ...D 18 LDV GRY 1 BLUE 3 FDV WHT 1 RED 19 FDV WHT 1 BLUE 4 GND YLW 1 RED 20 VINIT YLW 1 BLUE 5 N C PINK 1 RED 21 INTEG PINK 1 BLUE 6 D0 OR 2 RED 22 D0 OR 2 BLUE 7 D1 WHT 2 RED 23 D1 GRY 2 BLUE 8 D2 WHT 2...

Page 43: ...C 23 N C 5 N C 24 N C 6 D0 OR 2 RED 25 D0 OR 2 BLUE 7 D1 GRY 2 RED 26 D1 GRY 2 BLUE 8 D2 WHT 2 RED 27 D2 WHT 2 BLUE 9 D3 YLW 2 RED 28 D3 YLW 2 BLUE 10 D4 PINK 2 RED 29 D4 PINK 2 BLUE 11 D5 OR 3 RED 3...

Page 44: ...Industrial Products Division PULNiX America Inc 1330 Orleans Drive Sunnyvale CA 94089 Tel 408 747 0300 Tel 800 445 5444 Fax 408 747 0660 Email imaging jaipulnix com www pulnix com...