background image

  

 

RoIP-102 User Manual 

V. Default Factory Settings 

The  table below  shows the  factory  default settings.There  are  two way  to  reset to  the  factory 

default settings: 

i.    Press the RESET switch for more than 15 seconds. 

ii.    In the Configuration paga,select Tools and then Reset Config. 

Item 

Factory Default Settings 

Range 

Login ID 

Login Password 

admin 
admin 

Programmable(16 

characters in the ASCII 

table) 

WAN Port Setting 

LAN Port Setting 

PTT State 

DHCP 

192.168.8.1 

0

is active 

“0” is active low 

“1” is active high 

PTT maximum duration 

Jitter Delay 

60 seconds 

60 milliseconds 

Less than 600 seconds 

20-220 milliseconds 

Summary of Contents for ROIP102 Series

Page 1: ... Manual Cross Network Gateway Radio VoIP Public Announce User Manual ROIP102 Series Version 1 0 2011 4 9 For environmental protection please view this manual electronically and only print the pages you need RoIP 102 ...

Page 2: ...ortant Notices 3 II Gift Box Check List 4 III Overview 5 IV Installation 7 V Default Factory Settings 10 VI Device Configuration Via Built in Web Server 11 VII Call settings 14 VIII Application Examples 17 IX Hardware Specifications 20 ...

Page 3: ...t your local regulations in order to use this product legally iii This product requires the use of dynamic DNS DDNS service For testing purpose this DDNS service is temporary provided for free by Skyline Technology How ever this service is not guaranteed without any interruptions Customers are urged to build their own DDNS server or obtain this service from a DDNS provider Free DDNS server softwar...

Page 4: ...unpacking the gift box please check carefully that all items listed below are included Please report to your supplier for any missing items immediately 1 PPT Adapter Cables 1 AC DC Adapter Input 110 220 VAC Output 12VDC 2A 1 Main Unit 1 Ethernet Cable ...

Page 5: ...e radio world to the VoIP world and the cellular world easily It truly makes voice communications across multiple networks possible RoIP 102 basic version is a more compact more practical high tech multiple network Radio Cellular VoIP equipment which access to a group no GSM module simply complete the radio voice signals into IP signals access to the Professdional Edition or Stardard Edition RoIP ...

Page 6: ... The diagram above demonstrates A to use with the conference system RoIP302M as a central switching point the other three regions using RoIP102 Through this link ABCD four areas to achieve multi region interconnections among RoIP Series gateways iii Model Nomenclature ...

Page 7: ... 1A ii LED Indicators LED Power RUN Function Pwoer RoIP Status Description Lights up when the power is connected Flashes every 4 s indicates the device is not ready Flashes every 2 s indicates the device is ready LAN PC LAN port status PC port status Lights up when the LAN port is connected Blinks when there are data transmissions Lights up when the PC port is connected Blinks when there are data ...

Page 8: ...ort is 6 pin RJ 11 Socket 1 PTTOUT 2 GND 3 Vin RX 4 Aout TX 5 GND 6 PTTIN iv PTT Adapter Cable wiring Diagram v Switch Port The built in relay switch is connected to the middle two pins of the RJ 11 socket It acts as an ON OFF switch for the external system connected ...

Page 9: ...used to switch on and off a Public Announce PA system to instant broadcast If the relay switch is connected to high voltage load The maximum rating for the internal relay is 240VAC and 500 mA load current Connect the LAN Port to a local PC or a local Ethernet network LAN This allows sharing the external network connected to the WAN Port with the local network However the shared network is intended...

Page 10: ...5 seconds ii In the Configuration paga select Tools and then Reset Config Item Factory Default Settings Range Login ID Login Password admin admin Programmable 16 characters in the ASCII table WAN Port Setting LAN Port Setting PTT State DHCP 192 168 8 1 0 is active 0 is active low 1 is active high PTT maximum duration Jitter Delay 60 seconds 60 milliseconds Less than 600 seconds 20 220 milliseconds...

Page 11: ...inistrative level is admin and the default password is admin Please make sure to click on Save Changes after configuring the device Method 2 is to access the built in web server via the WAN port The WAN port is set to DHCP mode as a default factory setting When it is first connected to a network with a DHCP host it obtains an IP address automatically from the host In order to listen to the IP obta...

Page 12: ...the WAN port to PPPoE the corresponding usename and password to complete the following chart iii DDNS Settings If you use dynamic IP dees not depend on the exchange server the user can use the DDNS service is provided free of charge s dynamic IP address resolution services by SKYLINE If you use dynamic IP does not depend on the exchange with server the user can use the DDNS service DDNS service is...

Page 13: ...RoIP 102 User Manual www device serial number com ...

Page 14: ...int connection any RoIP102 as a Host to other terminal login and the host itself need to log into owns IP address Host set up own s phone number to be called by another terminal The terminal need to log in to the host must have to set themselves phone number for identification iii Call Settings Group 1 is to set the group number Each RoIP1102 need to set a number Group SIP Number is connected to t...

Page 15: ... accurate selection PTT Output Expiry second is to protect the station will launch as a means for long press the specific needs of the setting v Recorder Settings Redorder Setting is set for each group recording audio server address need to recording refer to the recording software instructions vi Broadcasting Settings Broadcasting Settings is actually seeting the password for Radio remote switch ...

Page 16: ...eceives the PA OFF Password it turns off the relay to deactivate the PA system The duration for the relay to be in the ON state is limited by the value set in the parameter PA ON Expiry This mechanism shuts down the PA System automatically The PA Control Group defines which group has the control over the relay switch Only the radio terminals in the group specified can broadcast to the PA System Al...

Page 17: ...e RoIP302 LAN port This fixed IP must be in the same segment as the LAN port of the ADSL Router For example if the LAN of the ADSL Router has an IP 192 168 1 1 then the LAN port RoIP302 could be set to 192 168 1 101 iv Configure the DMZ mode of the ADSL Router to fixed IP assigned to the RoIP302 LAN port For DMZ configuration please refer to the User Manual of the Router v Login to the RoIP Webpag...

Page 18: ...nd output RMS so PTT settings are A set for the host the number is set to 101 the body number is ROIP2010060005 DDNS and call setup is as follows DDNS Settings Call Settings B body number ROIP20100610006 the DDNS and call settings is as follows DDNS Settings ...

Page 19: ...the best sound quality for Communications so both sides have chosen alaw as speech coding Complete the connection save the configuration after the restart RoIP102 open the Radio the two place can Communications After connecting through the respective end of the potentiometer adjustment adjust the volume to the best sound quality DMZ s Settings please refer to the router manual ...

Page 20: ... Design CPU ARM9 RAM 16MB FLASH 4MB DSP 116 MHz 16 Bit Bus iii T Interface PTTIN Active Low 0 7V 4 7KΩ load PTTIN Active High 1 2V PTTOUT High Output 5V 4 7 KΩ load PTTOUT Low Output 0V APUT Output 8Ω 750mW 5V P P AIN Input 600Ω Internal Impedance 0 0 6Vp t p ADJOUT on the Adapter Cable 2KΩ Potentiometer RAM 16MB PTTIN Circuit Based on the circuit above the PTT Input level is high when it is open ...

Page 21: ...ported IEEE802 1p IP Standard IPV4 v Firmware Item OS Description Linux Remark Version 2 6 IP Voice Protocol Network Protocol SIP 2 0 IP TCP UDP HTTP ICMP DHCP CL SRV NTP TFTP ToS telnet Include SIP INFO extension Codecs G 711 a μ G 729A G 729AB G 723 1 GSM Html XML2 0 JAVA Configuration GUI ...