![PTN TPUH-PSU12 User Manual Download Page 15](http://html1.mh-extra.com/html/ptn/tpuh-psu12/tpuh-psu12_user-manual_1623421015.webp)
Integrated Switching Power Supply
PTN Electronics Limited 11 www.PTN-Electronics.com
Note:
After sending the
“Output/[x]V/[y].”
to change the output voltage, the
corresponding output channel will be switch off,
the command “
[x]@.”
should be
sent to switch on this output channel again.
After sending the
“LockKeyboard[x].”
to lock the front panel, the device can be
controlled via RS232 commands and GUI.
5.3 GUI Control
In addition to control the product via front panel button and RS232 communication
software. This product can be controlled via GUI. It allows users to interact with the
product through graphical icons and visual indicators.
1)
Connect a PC to the TCP/IP port on the rear panel, and set its network segment to
the same as the default IP of the product (192.168.0.178, port No.: 4001).
Same network
segment as the
product.