PTN TPUH-PSU12 User Manual Download Page 10

Integrated Switching Power Supply                                         

             

 

PTN Electronics Limited                                6                    www.PTN-Electronics.com 

5. System Operation 

5.1 Button Control 

 

Switch on/off output channel: 

Press the button

 01~12

 on front panel to switch on/off the corresponding output channel. 

 

 

Lock/unlock output channel: 

Long-press the button

 01~12

 for 3 seconds or more on front panel to lock/unlock the 

corresponding channel, and then the corresponding LED will flash 3 times. 

Note:

 

The locked channel can’t be controlled via front panel button

RS232 commands 

and GUI. 

 

 

Select the output voltage: 

Press 

SELECT 

on corresponding output channel to select the output voltage as 5V, 12V 

or 24V.   

Note: 

After switching the output voltage, the output channel will be turned off based on 

overvoltage protection control, and it need to be turned on again via the corresponding 
output channel switching button on front panel. 

 

 

Restore Factory Defaults: 

On rear panel, simultaneously long-press 

SELECT

 on channel 01 and channel 02 for 3 

seconds or more, the device will be restored to factory setting. 

 

5.2 RS232 Control 

Connect a PC to the RS232 port on the rear panel, and then install the RS232 control 
software on the PC, the product can be controlled by sending RS232 commands via the 
RS232 control software. 

 

5.2.1 RS232 Control Software 

 

Installation 

Copy the control software file to the computer connected with the 

product. 

 

Uninstallation 

Delete all the control software files in corresponding file path. 

 

 

Summary of Contents for TPUH-PSU12

Page 1: ...www PTN electronics com TPUH PSU12 Integrated Switching Power Supply All Rights Reserved Version TPUH PSU12_2018V1 4 User Manual ...

Page 2: ...l are acknowledged as the properties of the trademark owner No part of this publication may be copied or reproduced without the prior written consent of PTN Electronics Limited FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been tested ...

Page 3: ...e the unit to rain moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards Install the device in a place with fine ventilation to avoid damage caused by overheat Keep the module away from liquids Spillage into the hou...

Page 4: ...4 System Connection 5 4 1 Usage Precaution 5 4 2 System Diagram 5 5 System Operation 6 5 1 Button Control 6 5 2 RS232 Control 6 5 2 1 RS232 Control Software 6 5 2 2 Basic Setting 7 5 2 3 RS232 Communication Command 8 5 3 GUI Control 11 5 3 1 Control Menu 12 5 3 2 Voltage Setting Menu 13 5 3 3 Network Menu 13 5 3 4 Password Menu 14 5 3 5 GUI Update 14 6 Panel Drawing 15 7 Troubleshooting Maintenanc...

Page 5: ...T Switch on rear panel RS232 command or GUI 1 1 Feature Double input channel designed for ensuring the stable AC source Total 12 output channels and each channel has three kinds of output voltage 5 12 24VDC can be selected Output channels can be switch on off by via the front panel buttons RS232 commands or GUI Output voltage 5 12 24VDC can be selected via the TACT Switch on rear panel RS232 comma...

Page 6: ... 24V 22 8 25 2V Maximum output power consumption of signal channel 5V 12W 12V 15W 24V 15W Maximum output power consumption for single supply 180W Maximum output power consumption for dual supply 180W Control Part Buttons Control Front Panel 01 12 total 12 buttons Rear Panel Total 12 TACT Switches named SELECT RS232 Control RS232 port 3 Pin phoenix connector Baud rate support 9600 GUI Control TCP I...

Page 7: ...input voltage is too low or too high 01 12 Output channel switching buttons and Activity LEDs 12 in total Press the button to trun on off the corresponding channel and the corresponding LED will turn green and keep on Long press the button for 3 seconds or more to lock unlock the corresponding channel and then the corresponding LED will flash 3 times Note Pictures shown in this manual are for refe...

Page 8: ...sed Blinking fastly when the current channel is short circuit or over voltage RS232 Serial port 3 Pin phoenix connector connect with a control device such as PC to control the product via RS232 commands TCP IP Ethernet port connect with PC to control the product via GUI AC1 AC2 2 AC input channels Input voltage is AC100 240V Note Pictures shown in this manual are for reference only different model...

Page 9: ...of the power switches plugs sockets and power cords should be insulated and safe All devices should be connected before power on 4 2 System Diagram AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5...

Page 10: ... as 5V 12V or 24V Note After switching the output voltage the output channel will be turned off based on overvoltage protection control and it need to be turned on again via the corresponding output channel switching button on front panel Restore Factory Defaults On rear panel simultaneously long press SELECT on channel 01 and channel 02 for 3 seconds or more the device will be restored to factory...

Page 11: ...tware CommWatch exe as example The icon is showed as below The interface of the control software is showed as below Please set the parameters of COM number bound rate data bit stop bit and the parity bit correctly and then you are able to send command in Command Sending Area Parameter Configuration area Monitoring area indicates if the command sent works Command Sending area ...

Page 12: ...en x Switch off the output channel x x 1 12 x Closed Output x V y When y NULL Set the output voltage as x for all output channels x 5 12 24 All Output x V When y 1 12 Set the output voltage as X for the output channel y x 5 12 24 y Output x V Status x When x NULL query the on off status of all output channels 01 Open 02 Closed 03 Closed When x 1 12 query the on off status of the output channel x x...

Page 13: ...ear x When x NULL clear the data of all Group Clear All When x 1 5 clear the data of the Group x Clear F x QueryGroup x When x NULL query all groups Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm1 12 12 12 12 12 12 12 12 12 12 12 12 Vm2 XX XX XX XX XX XX XX XX XX XX XX XX When x 1 5 query the group x Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm x 12 12 12 12 12 12 12 12 12 12 12 12 0911 Restore Factory ...

Page 14: ... Locking all channel When x 1 12 unlock the channel x Locking x channel LockKeyboard x When x 0 unlock the front panel Unlocking keyboard When x 1 lock the front panel Locking keyboard FA XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX FE Modify product name The command has 18 bytes in total and 16 bytes are effective The digit 0 is used for padding For example FA 50 54 4E 00 00 00 00 00 00 00 00 ...

Page 15: ...to lock the front panel the device can be controlled via RS232 commands and GUI 5 3 GUI Control In addition to control the product via front panel button and RS232 communication software This product can be controlled via GUI It allows users to interact with the product through graphical icons and visual indicators 1 Connect a PC to the TCP IP port on the rear panel and set its network segment to ...

Page 16: ...log in interface shown as below 5 3 1 Control Menu Type user name user and password user default setting on the log in interface and then click Login to enter Control menu shown as below Select the ON OFF to switch on off the output channel Click the All On to switch on all output channels Click the All Off to switch off all output channels ...

Page 17: ...ter voltage setting menu shown as below Lock Unlock the output channel When the port is locked its voltage cannot be switched Select 5V 12V or 24V output voltage for each output channel 5 3 3 Network Menu Click Network on the top of page to enter network setting menu shown as below Dynamic or static IP mode can be selected Under static IP mode IP address and ...

Page 18: ...y the password as you need Lock Unlock front panel buttons 5 3 5 GUI Update GUI for the Scaler Switcher supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to Upload Program as shown ...

Page 19: ...0 11 12 AC 2 AC 1 AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 437 mm 357 mm 44 mm ...

Page 20: ...mmunication parameters Type in correct RS232 communication parameters Fail or loose connection Make sure the connection is good Broken RS232 port Send it to authorized dealer for checking Cannot control the device by front panel buttons while can control it through RS232 port The front panel buttons are broken Send it to authorized dealer for repairing Cannot control the device via GUI The IP addr...

Page 21: ...n caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product model showed on the warranty card does not match with the model of the product for repairing or had been altered Damage caused by force majeure Servicing not authorized by distributor Any other causes which does not relate to a product defect Shipp...

Page 22: ......

Page 23: ......

Page 24: ...www PTN Electronics com PTN Electronics Limited Tel 86 755 2846 1819 Fax 86 755 8471 7796 Email info PTN electronics com Website www PTN electronics com ...

Reviews: