PT610, PT620, PT630
Instruction Manual
12
4.2.1 OPENING/CLOSING THE HOUSING
Make sure that the mechanical installation of the instruments is done properly and the environment is
suitable to open the housing (the housing should not be opened if there is a chance of dirt or water
entering the housing).
Open the housing from its rear. The rear part of the housing will be connected to the top part of the
housing with two stainless steel wires.
Warning:
When closing the housing make sure the weatherproofing seal is positioned correctly, ensure
the seal is free of any debris and the screws are tightened progressively to 0.4-0.5Nm (3.5-4.5 in-lb).
4.3 INTERNAL CONNECTIONS
For reference the illustration below shows the general layout of main board of the indicator and the
connections.
Note
:
The Ethernet port is not present on the PT610 and PT620. Not all options fit all indicators.
Load
Cell
Mains Power
RS232C-1
RS232C-2
RS485
Calibration
DIP switch
Alibi
Memory
Ethernet
Port
Modbus
Option
Option Board
Connection
Second
Scale
USB
Port
Automatic
Power On