Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
C-41
Appendix C: Bar Code Settings
Decoded (Intermec ISCP)
Codablock
Code 128 Emulation
When this parameter is enabled, the scanner transmits data from certain Micro PDF-417
symbols as if it was encoded in Code 128 symbols.
If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted
with one of the following prefixes:
]C1 if the first codeword is 903-907, 912, 914, 915
]C2 if the first codeword is 908 or 909
]C0 if the first codeword is 910 or 911
If Code 128 Emulation is set to
off
, the Micro PDF-417 symbols are transmitted with one of
the following prefixes:
]L3 if the first codeword is 903-907, 912, 914, 915
]L4 if the first codeword is 908 or 909
]L5 if the first codeword is 910 or 911
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-14 for details.
C.3.23 Codablock
Enable Codablock A
Set this parameter to
on
to enable “Codablock type A”.
Enable Codablock F
Set this parameter to
on
to enable “Codablock type F”.
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-14 for details.