Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
C-37
Appendix C: Bar Code Settings
Decoded (Intermec ISCP)
Discrete 2 of 5
Minimum Length
Minimum lengths for the bar code can be set from
0
to
255
. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).
Length Restriction
Refer to “Length Restriction” on page C-14 for details.
Add/Remove Data
Refer to “Add/Remove Data” on page C-14 for details.
C.3.16 Discrete 2 of 5
Enabled
Set this parameter to
on
to enable “Discrete 2 of 5”.
Standard 2 of 5 Format
This parameter allows you to choose a standard format—either
Identicon
(6 start/stop bars)
or
Computer Identics
(4 start/stop bars).
Check Digit Verification
The available options for this parameter are
Disabled
and
MOD 10 Check
. “Check Digit
Verification” uses the specified algorithm of the option you've chosen to ensure the integrity
of the symbol data before transmitting. If the data does not contain that algorithm, the data is
not transmitted.
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Set Length L1, Set Length L2, and Set Length L3
Lengths for “Discrete 2 of 5” can be set from
0
to
255
. The length of a code refers to the
number of characters (i.e., human readable characters), including check digit(s).
Double-tapping on these parameters displays dialog boxes where you can define the code
length that will be recognized by your scanner.
Length Mode
You can chose to set L1 as
Minimum Length
or L1,L2,L3 as
Fixed Length
.