C-26
Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
Appendix C: Bar Code Settings
Decoded (Intermec ISCP)
Decoded (ISCP) Advanced Options
C.3.2
Decoded (ISCP) Advanced Options
Continuous Scan Mode
Setting this parameter to
on
keeps the laser on and continuously decoding as long as the
scanner button is pressed and held down.
Minimum Cancel Time
The value assigned to this parameter determines the time delay before the scanner is turned
off, once the scanner trigger or button is released. This gives the scanner a minimum amount
of time to complete its current decode before the scan is cancelled when you quickly trigger
on/off.
Low Power Timeout
To extend laser life, you can select the time the scanner remains active following a success-
ful decode. The scanner wakes from low power mode when a bar code is scanned—a
successful decode restores normal flashing.
When you double-tap on this parameter, a dialog box is displayed in which you can choose a
value of
30 sec, 1 min, 2 min
, or
3 min
.
Parameter Scanning
Setting this parameter to
Enabled
allows decoding of parameter bar codes.
Same Read Validate
The data is only transmitted after repeated reads give the same result. The value assigned at
this parameter determines the number of reads required, from
0
to
10
times.
Same Read Timeout
Prevents the same bar code from being read more than once. The value assigned determines
after what time period the scanner will timeout, from
0
to
2550 msec
.
Diff Read Timeout
Prevents unwanted reading of other bar codes on the same label. The value assigned deter-
mines after what time period the scanner will timeout, from
0
to
2550 msec
.
Note: This parameter is only used if the Trigger Mode has been set to
Continuous On