C-12
Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
Appendix C: Bar Code Settings
Decoded (Internal) Scanners
Code 39
C.2.5
Code 39
Enabled
Setting this parameter to
on
enables “Code 39”.
Enable Trioptic Code 39
Trioptic Code 39 symbols always contain six characters. Setting this parameter to
on
allows
this type of symbology to be recognized.
Convert To Code 32
Setting this parameter to
on
allows the scanner to convert the bar code from “Code 39” to
“Code 32”.
Code 32 Prefix
When this parameter is enabled, the prefix character “A” is added to all “Code 32”
bar codes.
Set Length L1 and Set Length L2
Lengths for “Code 39” can be set for
Any length
,
Length within a range
,
One discrete length
or
Two discrete lengths
. The length of a code refers to the number of characters (i.e., human
readable characters), including check digit(s).
Double-tapping on these parameters displays dialog boxes labelled
Set Code Lengths
where
you can define the code length that will be decoded by your scanner.
Note: “Trioptic Code 39” and “Full ASCII” should not be enabled simultaneously. The
scanner does not automatically discriminate between these two symbologies.
Note: “Code 39” must be enabled in order for this parameter to function.
Note: “Convert to Code 32” must be enabled in order for this parameter to function.