Installation
The charger can be wall mounted using the wall mount kit (MT2031) or it can be operated
on a flat surface. Install the charger in an area that is free from excessive dirt, dust and con-
taminants. The ambient temperature must be in the range 5°C to 39°C (41°F to 102°F). The
charger will not charge batteries outside of this temperature range. For maximum perfor-
mance, it is recommended that the charger be operated at room temperature—a temperature
range between 18°C to 25°C (64°F to 77°F).
The charger can consume up to 6 A at 120 VAC, 3A at 240 VAC. Check to ensure the mains
circuit supplying the charger is adequate for this loading (especially if several chargers are
being powered from the same circuit). After unpacking the unit:
•
Visually check the charger for damage.
•
Install the IEC power cord and apply power.
All charge indicators flash momentarily at powerup to indicate that the charger is ready for
operation.
If you choose to wall mount the charger, detailed installation instructions are included in the
Omnii 6-Slot Battery Charger ST3006
Quick Start Guide (PN 8000204)
included with the
charger kit. Be sure to locate the charger in an area where there is no risk of injury to persons
walking in the vicinity.
6.8.2
Operator Controls
The gang charger does not have operator controls or a power switch. There is no dedicated
indicator light to show that the charger is powered, but the charge slot LEDs will light.
6.8.3
Charge Indicators
Each battery charge slot is equipped with four LEDs to indicate the charge status of the bat-
tery. When the Omnii batteries are inserted in the charger, the colour and behaviour of the
LEDs associated with the charge wells in use indicate the status of the charge.
Important: Use IEC-320 C13 power cords approved by Psion Teklogix, with the ground
pin connected to a proper earth-grounded receptacle. Check with a quali-
fied electrician if you are uncertain of your receptacle grounding.