background image

PS36L

-

P7

PS36L-P7

NOTE: 

to PowerTec Solutions Models PS36L-K7 (Next Generation FTTx Micro UPS)
and all package accessories as listed below.

The reference to "NXG-Vision" within this User Manual refers 

NXG-Vision INTRODUCTION

(when ordered with optional Universal )DC power supply and battery 
back up device for Indoor 12Vdc Optical Network Terminals (ONT).
 The NXG-Vision not only provides constant supply of DC power during
 normal operating conditions, but offers battery backup power in case of
 electrical power outage. NXG-Vision also provides customer facing
 Network Interface Reset Intelligence to provide integrated ONT reset 
 technology designed to reduce Provider OPEX.

NXG-Vision is designed and intended for use as Desktop or Wall-mount

 

 Please verify all standard contents are accounted for upon receipt of

 NXG-Vision. STANDARD: (1) Power Supply/Charger; (1) Li Ion Battery Pack;

 (1) AC Power Cord; (1) 7-Pin Connector; (1) User's Manual;Optional:
 (1) Universal Wall Mount Enclosure w/ Cover.

NOTE:

PS36L-P7

                                         

 

VISUAL

 

INDICATORS

1

Battery

Color Red

-

Service or replace battery

or battery is not

installed

 

in

 

NXG

-

Vision

.

   

 

 ,

 

   

 

2

Mute

Color-Yellow

Flashing Audible Alarm silenced for 24hrs.
Soid

-

Audible

 

Alarm

 

Silence Until manually

 enable.

-

 

 

 

 

 

  

3

DC

Color Green

-

NXG Vision is working off Standby Power.

-

   

 

 

 

4

System

Status

Color- Green

NXG Vision is Recieving AC power load to

 

operate

 

under

 

normal

 

conditions.

-

   

 

 

 

 

                                             CONTROL SWITCHES

  5

  6

 

  7

 

4

3

2

1

5

6

7

      

VISUAL AND AUDIBLE

 

STATUS

/

ALARM

 

SIGNALS

STATE

    VISUAL

 INDICATOR

AUDIBLE

INDICATOR

DESCRIPTION

    Normal

System 

Status

Indication On

Operating under normal AC
line power load

 

and

 

conditions

charges battery

.

Battery

 

is

 

connected

 

and

 

in good

 

condition

.

 

 

  ON Battery

DC

Indicator

 

On

 

AC line power failure
or AC cord

disconnection

.

NXG

-

Vision

 

is being supplied

 

with battery

 

power

.

 

 

 

 

   Replace
   Battery

Battery

Indicator On

 

1 2 second audible
indicator

 

every 15

 

min.

/  

 

Replace faulty or end of
life battery.

 

 

   

     Battery

Missing

 Battery

           

Indicator On

NXG Vision is operating
on AC

 

line power only

 

without

 

available

 

stanby power

 

for

 

outage

 

scenario

.

When battery

 

is removed

 

from

 

unit

,

battery

 

indicator

 

will

 

illuminate after 5

 

sec

.

-

   

 

Low Battery

 

 DC Indicator
    Flashes

 

1 2 second audible
indicator

 

4 times

 

per minute.

/  

 

Battery has reached equal
to

 

or less

 

than

 

30

remaining

 

capacity on

 

battery

 

discharge

.

 

 

 

Review the following important safety warnings to avoid bodily injury or damage
 to equipment during installation or operation of this device.
Read ALL instructions before attempting to install or operate this device.

This device is intended for indoor use only. To prevent the risk of fire or
 eletrical shock, install in dry location free from damp or wet environment,
 or potentially damp or wet environment.

Adhere to all acceptable operating environment limitations as listed to
 prevent the risk  of fire or electrical shock (see user specifications
 within User's Manual)

Risk of fire or explosion if improper battery pack is installed and 
attempted to operate with this device. Device is rated and approved for
use with PowerTec Solutions Internation Li Ion Battery Pack ONLY.
Follow User Manual instructions for proper installation and removal of
battery pack.

NO user-replaceable parts within this device. Do not remove cover for
any reason.

Allows NXG Vision to cold start power off
Battery

 

Pack

 

when

 

AC

 

line

 

power is

 

not

 

present

 

and

 

new

 

or

 

replacement

 

pack

 

is

connected

,

press

 

and

 

hold

 

for

 

3

 

seconds

.

 

-

   

 

 

 

 

Allows for DC line power reset of optical
Network

 

terminal.Press

 

and hold

 

for

 

3

seconds

 

to

 

reset

/

reboot optical

 

newwork

terminal.

 

 

 

 

 

   

 

  Alarm
Silence

Cold
Start

N.I.R.
Reset

Disables Audible Alarm function. Press and release 
to disable Audible Alarm for 24 hours. Press and hold
for 15 seconds to disable Audible Alarm indefinitely.
 Press and hold for another 15 seconds in order to
 re-enable Audible Alarm function.

Reviews: